Dokumentationszentrum
Datenblätter, technische Infoblätter, Zertifizierungsdokumente und mehr.
IQ Gateway software version 7.6.323 supports grid-tied storage systems with the IQ8 Series Microinverters along with IQ Battery 3T or 10T for Greece, Germany, and Austria. It can be integrated with an IQ Energy Router to monitor and control residential loads, like EV chargers and heat pumps, for Germany and Austria. The released software supports grid-tied, solar-only systems with IQ8HC Microinverters in India and grid-tied, solar-only systems with IQ8 Series Microinverters in Switzerland. This release enables the consumption CT-based Phase Imbalance Management (PIM) as the default method for complying with phase-balancing requirements.
-
Gateways supported: IQ Gateway Metered, IQ Gateway Standard
-
Countries: Greece, Germany, Switzerland, India, and Austria
-
Microinverters supported: IQ8 Series (IQ8MC-72-M-INT, IQ8AC-72-M-INT, IQ8HC-72-M-INT, IQ8PLUS-72-M-INT, IQ8M-72-M-INT), compatible third-party string inverters
-
Supported system configurations:
-
Grid-tied solar only system with IQ8HC Microinverters and IQ Gateway Metered in India
-
Grid-tied solar only system with IQ8 Series Microinverters and IQ Gateway Metered in Greece, Germany, Switzerland, and Austria
-
Grid-tied solar and storage system with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T in Greece, Germany, and Austria
-
Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T in Greece, Germany, Switzerland, India, and Austria
-
Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, IQ Energy Router, and IQ Battery 3T/10T for Germany and Austria
-
Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, IQ Energy Router, and IQ Battery 3T/10T for Germany and Austria
-
Release notes:
# |
Feature |
Description |
1 |
IQ Battery support |
Supports IQ Battery 3T or 10T along with IQ8 Series Microinverters in Greece. |
2 |
IQ8 Series Microinverters support |
Support for IQ8 Series Microinverters (SKUs: IQ8MC-72-M-INT, IQ8AC-72-M-INT, IQ8HC-72-M-INT, IQ8MC-72-M-ACM-INT, IQ8MC-72-M-ACM-INT-NM, IQ8MC-72-M-ACM-INT-RMA) in Greece, Austria, and Switzerland, as well as the IQ8HC-72-M-INT Microinverters in India. |
3 |
Compliant with phase-balancing requirements to maintain imbalance between phases within the threshold limits. |
|
This release is being deployed via remote software upgrades for new and existing systems.
IQ Gateway software version 7.6.125 now supports grid-tied IQ Batteries in Austria.
-
Gateways supported: IQ Gateway Metered
-
Countries: Austria, Belgium, and Germany
-
Microinverters supported: IQ7 Series
-
Supported system configurations:
-
Grid-tied solar and storage system with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T for Austria, Germany, and Belgium
-
Release notes:
# | Feature | Description |
---|---|---|
1 | Support for Austria | Grid-tied IQ Battery 3T/10T is now available in Austria. |
2 | Increases battery capacity available for self-consumption | Enphase Energy System owners can now use more of their battery capacity for self-consumption. Gateway software 7.6.125 enables batteries to discharge to 2% State of Charge (SoC) during normal operation. Previously batteries were restricted to discharge to 10% SoC to maintain battery health. The 7.6.125 software includes firmware version 2.1.29 for the Battery Management Unit (BMU) which ensures battery health even when discharging down to 2% SoC. |
This release is being deployed via remote software upgrades for existing systems.
Der IQ Combiner 3P EU entspricht der Norm IEC61439-3. Die Konformität der einzelnen Komponenten des IQ Combiner kann dem Datenblatt entnommen werden.
Bringen Sie die Stromwandler für die Produktion an den Kabeln zwischen Leitungsschutzschalter und Fehlerstrom-Schutzschalter an. Dadurch wird sichergestellt, dass der kumulierte Stromwert aus beiden Zweigen der IQ Relays der PV-Anlage gemessen wird.
Ja, beim IQ Combiner 3P EU ist das Comms-Kit vorinstalliert. Das USB-Gerät sieht aus wie ein Repeater. Es handelt sich jedoch um das Comms-Kit ohne das übliche Gehäuse (kompakte Bauweise).
Beim IQ Combiner 3P EU sind 3-phasige IQ Relays (Q-RELAY-3P-INT) vorinstalliert.
Beim IQ Combiner 3P EU ist das IQ Gateway Metered (ENV-S-EM-230) vorinstalliert.
Der IQ Combiner 3P EU ist derzeit in den folgenden neun Ländern erhältlich: Deutschland, Österreich, Schweiz, Niederlande, Frankreich, Belgien, Spanien, Polen und Portugal.
(Hinweis: Dieses Produkt wurde für den EU-Raum entwickelt und ist möglicherweise in Zukunft in weiteren Ländern erhältlich. Bitte informieren Sie sich auf den länderspezifischen Webseiten über die aktuelle Verfügbarkeit.)
4-poliger Fehlerstrom-Schutzschalter, 30 mA, 63 A, Typ A, für Erdschlussschutz.
4-polige Leitungsschutzschalter, 20 A, Kennlinie B.
Die Kurzinstallationsanleitung des IQ Combiner enthält alle erforderlichen Informationen über die für die Einrichtung relevanten Komponenten. Installationsanleitungen für die einzelnen Komponenten sind im Dokumentationszentrum erhältlich.
Ja, bei einer Anlage dieser Art müssen Sie jedoch den Stromwandler für die Produktion an den Zuleitungen der String-Wechselrichter anbringen.
Der IQ Combiner 3P EU ist nur für die Installation in geschlossenen Räumen vorgesehen.
- Öffnen Sie die Tür so weit wie möglich.
- Hängen Sie die Tür im Scharnier aus, indem Sie sie in Richtung der Scharnieröffnung ziehen.
- Legen Sie sie an einem sicheren Ort in der Nähe des Installationsstandortes ab.
Die Kunststoffscheibe verschließt die Öffnung auf der Frontabdeckung, hinter der sich das IQ Gateway befindet. Bringen Sie die Scheibe nach Abschluss der übrigen Installation an.