Support center

Download data sheets, tech briefs, installation guides, and more.



Filter by
Region
Your selection (25)
All Communication
(25)
Changes and improvements in software updates
IQ Gateway software release notes (8.2.4393)
January 9, 2025

IQ Gateway software version 8.2.4393 supports grid-tied (without backup) Solar Only systems, grid-tied solar and storage systems, and grid-forming (with backup) solar and storage systems. It also supports IQ8 Series, IQ7 Series, and/or S Series Microinverters, or third-party string inverters, along with IQ Battery 5P and IQ System Controller 3 INT.

  • Countries: Australia and New Zealand
#FeatureDescription
1Emergency backstop support in Victoria, via Common Smart Inverter Profile Australia (CSIP- AUS) for Solar Only systems or solar and storage systems with IQ7 or IQ8 Series MicroinvertersThe feature allows distribution network service providers (DNSPs) to remotely turn down or switch off rooftop solar systems in emergency situations when high solar export levels compromise grid stability. The Victorian emergency backstop via CSIP-AUS and IEEE 2030.5 communication standard is now supported.
2System stability improvements
  • Improved phase imbalance management (PIM) for solar and battery systems.
  • Improved handling of grid transitions to ensure consistent and reliable operation in all modes.
3IQ Battery 5P battery management unit improvements
  • Battery management units improved to enhance overall performance.
4Bug fixes and security enhancements
  • Battery SoC did not show correctly for sites with batteries connected to multiple IQ Gateways. This issue has been resolved.
  • Increased the amount and frequency of data reported to the Enphase Cloud to enable quick backfilling of missing data in energy graphs in the Enphase App.
  • Enhanced security features.
  • IQ System Controller 3 INT critical bug fixes.
  • Gateways supported:
     
    • IQ Gateway Metered
  • Microinverters supported:
     
    • IQ8 Series, IQ7 Series, S Series, and third-party string inverters (Grid-tied solar plus storage systems only)
  • Batteries supported:
     
    • IQ Battery 5P
  • System controllers supported:
     
    • IQ System Controller 3 INT
  • Supported system configurations:  
     
    • Grid-tied (without backup) Solar Only systems with IQ8 Series, IQ7 Series, and/or S Series Microinverters, and IQ Gateway Metered
    • Grid-tied (without backup) Solar Only systems with IQ8 Series, IQ7 Series, and/or S Series Microinverters, and IQ System Controller 3 INT
    • Grid-tied (without backup) solar and storage systems with IQ8 Series, IQ7 Series, and/or S Series Microinverters, or third-party string inverters, IQ Gateway Metered, and IQ Battery 5P
    • Grid-forming (with backup) solar and storage systems with IQ8 Series, IQ7 Series, and/or S Series Microinverters, IQ System Controller 3 INT, and IQ Battery 5P

This release is being deployed via remote software upgrades for all systems, excluding sites with AC Batteries (ACB), S Series Microinverters, and sites with older IQ Gateway models.

IQ Gateway software release notes (8.2.4401)
January 3, 2025

IQ Gateway software version 8.2.4401 supports backward compatibility of IQ8 Series Microinverters with existing IQ7 Series Microinverter sites in the countries mentioned below.

  • Countries: The United States, Puerto Rico, Canada, Mexico, Bermuda, Brazil, and the Philippines

    #FeatureDescription
    1Support for IQ7 and IQ8 mixed systems

    Supports backward compatibility of IQ8 Series Microinverters in the existing IQ7 Series Microinverter systems on the same IQ Gateway only in the following configurations:

    • Grid-tied (without backup) Solar Only systems
    • Grid-tied (without backup) solar and storage systems with IQ Battery 5P
    • Grid-tied (without backup) solar and storage systems with IQ Battery 3T/10T

    NOTE: IQ7 Series Microinverters cannot be added to a site with existing IQ8 Series Microinverters on the same gateway. A mixed system of IQ7 and IQ8 will not support IQ8-specific PCS features and grid-forming capabilities.

  • Gateways supported:
     
    • Puerto Rico and the United States:
       
      • IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES and IQ Combiner 4/4C (IEEE 1547-2018 compliant)
      • IQ Gateway and IQ Gateway (IEEE 1547-2018 compliant)
    • Brazil and Philippines:
       
      • IQ Gateway M
      • IQ Gateway (only for Brazil)
    • Canada, Mexico, and Bermuda:
       
      • IQ Combiner 5/4 and IQ Combiner 4 (IEEE 1547-2018 compliant)
      • IQ Gateway and IQ Gateway (IEEE 1547-2018 compliant)
  • Microinverters supported:
     
    • Puerto Rico and the United States:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2- US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2- US, IQ8M-72-M-US, IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS- 72-M-US, IQ8X-80-M-US)
      • IQ7 Series (all SKUs)
    • Canada, Mexico, and Bermuda:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2- US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2- US, IQ8M-72-M-US, IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS- 72-M-US, IQ8X-80-M-US (only for Canada))
      • IQ7 Series (all SKUs)
    • Brazil:
       
      • IQ8 Series (SKU - IQ8P-72-2-BR)
      • IQ7 Series (IQ7AM and IQ7Plus)
    • Philippines:
       
      • IQ8 Series (SKU - IQ8P-72-2-US)
      • IQ7 Series (all SKUs)
  • Batteries supported:
     
    • Puerto Rico and the United States:
       
      • Third-generation IQ Batteries: IQ Battery 5P
      • Second-generation IQ Batteries: IQ Battery 3T/10T
      • First-generation IQ Batteries: IQ Battery 3/10
    • Canada, Mexico, and Bermuda:
       
      • Third-generation IQ Batteries: IQ Battery 5P
      • Second-generation IQ Batteries: IQ Battery 3T/10T
  • Supported system configurations:  
     
    • Puerto Rico and the United States:
       
      • Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters & IQ7 Series Microinverters (mixed) and IQ Combiner 5/5C or IQ Combiner 4/4C (IEEE 1547-2018 compliant) or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway
      • Grid-tied (without backup) solar and storage systems with IQ8 Series & IQ7 Series Microinverters (mixed), IQ Battery 5P, and IQ Combiner 5/5C
      • Grid-tied (without backup) solar and storage systems with IQ8 Series & IQ7 Series Microinverters (mixed), IQ Battery 5P, IQ Combiner 4/4C (IEEE 1547-2018 compliant) or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway, and Communications Kit 2
      • Grid-tied (without backup) solar and storage systems with IQ8 Series & IQ7 Series Microinverters (Mixed), IQ Battery 3T/10T, IQ Combiner 5/5C or IQ Combiner 4/4C (IEEE 1547-2018 compliant) or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway, and Communications Kit 1
    • Canada, Mexico and Bermuda:
       
      • Grid-tied (without backup) Solar Only systems with IQ8 Series & IQ7 Series Microinverters (mixed), and IQ Combiner 5 or IQ Gateway (IEEE 1547-2018 compliant) or IQ Gateway
    • Brazil and Philippines:
       
      • Grid-tied (without backup) Solar Only systems with IQ8P and IQ7 Series Microinverters (mixed), and IQ Gateway M
      • Grid-tied (without backup) Solar Only systems with IQ8P and IQ7 Series Microinverters (mixed), or IQ8P Microinverters and IQ Gateway (only for Brazil)

This release is being deployed via the Enphase Installer App to systems with IQ8 Series and IQ7 Series (mixed) Microinverters.

IQ Gateway software release notes (8.2.4391)
December 11, 2024

IQ Gateway software version 8.2.4391 supports grid-tied (without backup) Solar Only and solar and storage systems. It also supports grid-forming (with backup) solar and storage systems with IQ8 Series, IQ7 Series, S Series and/or M Series Microinverters or third-party string inverters, along with AC Batteries, IQ Battery 3T/10T, or IQ Battery 5P and IQ System Controller 3 INT.

  • Countries: Australia, Denmark, Germany, Netherlands, New Zealand, and Sweden

    Denmark, Germany, Netherlands, and Sweden:

    #FeatureDescription
    1Bug fixesFor batteries connected to phases other than Phase A (Phase L1), the aggregate battery state of charge (SoC) was evaluated as zero. This issue has been fixed.

    Australia and New Zealand:

    #FeatureDescription
    1Emergency backstop support in Victoria via Common Smart Inverter Profile Australia (CSIP-AUS) for Solar Only systems or solar and storage systems with IQ7 or IQ8 Series Microinverters
    • To enable distribution network service providers (DNSPs) to remotely turn down or switch off rooftop solar systems in emergency situations when solar exports are too high, the Victorian emergency backstop via CSIP-AUS and IEEE 2030.5 communication standard is now supported.
    2System stability improvements
    • Improved phase imbalance management (PIM) for solar and battery systems.
    • Improved handling of grid transitions to ensure consistent and reliable operation in all modes.
    3IQ Battery 5P battery management unit improvements
    • Battery management units improved to enhance overall performance.
    4Bug fixes and security enhancements
    • Battery SoC did not show correctly for sites with batteries connected to multiple IQ Gateways. This issue has been resolved.
    • Increased the amount and frequency of data reported to the Enphase Cloud to enable quick backfilling of missing data in energy graphs in the Enphase App.
    • Enhanced security features.
  • Gateways supported: 
     
    • Denmark, Germany, Netherlands, and Sweden:  IQ Gateway Metered and IQ Gateway Standard
    • Australia and New Zealand: IQ Gateway Metered
  • Microinverters supported:
     
    • Denmark, Germany, Netherlands, and Sweden:  IQ8 Series, IQ7 Series, M Series, and compatible third-party string inverters
    • Australia and New Zealand: IQ8 Series, IQ7 Series, S Series, and third-party string inverters (Grid-tied solar plus storage systems only)
  • Batteries supported:
     
    • Denmark, Germany, Netherlands, and Sweden: IQ Battery 3T/10T, IQ Battery 5P, and AC Batteries
    • Australia and New Zealand: IQ Battery 5P
  • System controllers supported:
     
    • Australia and New Zealand: IQ System Controller 3 INT
  • Supported system configurations:  
     
    • Netherlands:
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied Solar Only systems with IQ8 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied Solar Only systems with IQ7 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied Solar Only systems with M Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
    • Denmark, Germany, and Sweden:
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and AC Batteries 
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and AC Batteries 
      • Grid-tied Solar Only systems with IQ8 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied Solar Only systems with IQ7 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied Solar Only systems with M Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
    • Australia and New Zealand:
       
      • Grid-tied (without backup) Solar Only systems with IQ8 Series, IQ7 Series, or S Series Microinverters and IQ Gateway Metered
      • Grid-tied (without backup) solar and storage systems with IQ8 Series Microinverters, IQ7 Series Microinverters, S Series Microinverters, or third-party string inverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-forming (with backup) solar and storage systems with IQ8 Series, IQ7 Series, or S Series Microinverters, IQ System Controller 3 INT, and IQ Battery 5P

This release is being deployed via remote software upgrades for all systems in Denmark, Germany, Netherlands, and Sweden.

For Australia and New Zealand, this release is being deployed via remote software upgrades for all systems, excluding sites with AC Batteries, M Series Microinverters, and sites with older IQ Gateway software.

IQ Gateway software release notes (8.2.4386)
November 25, 2024

IQ Gateway software version 8.2.4386 supports grid-agnostic systems with IQ8 Series and IQ7 Series Microinverters along with IQ Battery 5P and IQ System Controller 3 INT.

  • Countries: India and South Africa

    #FeatureDescription
    1IQ Battery 5P support along with IQ System Controller 3 INTSupports grid-agnostic solar and storage systems with IQ8/IQ7 Series Microinverters, IQ System Controller 3 INT, and IQ Battery 5P.
  • Gateways supported: IQ Gateway within IQ System Controller 3 INT
  • Microinverters supported: IQ8 Series and IQ7 Series Microinverters
  • Batteries supported: IQ Battery 5P
  • System controllers supported: IQ System Controller 3 INT
  • Supported system configurations:  
     
    • Grid-agnostic solar and storage systems with IQ8 Series Microinverters, IQ System Controller 3 INT, and IQ Battery 5P.
    • Grid-agnostic solar and storage systems with IQ7 Series Microinverters, IQ System Controller 3 INT, and IQ Battery 5P.

This release is being deployed via remote software upgrades for specified configurations.

IQ Gateway software release notes (8.2.4265)
November 22, 2024

IQ Gateway software version 8.2.4265, as part of factory-built gateways, supports grid-tied systems with IQ8 Series, IQ7 Series, and/or M Series Microinverters or third-party string inverters along with the IQ Battery 3T/10T, IQ Battery 5P, or AC Batteries.

  • Gateways supported: IQ Gateway Metered and IQ Gateway Standard
  • Countries: Albania, Austria, Australia, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, India, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Malaysia, Mauritius, Namibia, Netherlands, New Caledonia, New Zealand, Philippines, Poland, Romania, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Thailand, Turkey, Great Britain, and Vietnam

    #FeatureDescription
    1IQ Battery 5P supportThe factory-built gateways will support grid-tied solar and storage systems with IQ8/IQ7 Series Microinverters or third-party string inverters and IQ Battery 5P in Belgium, France, Great Britain, Italy, Luxembourg, and Netherlands.
    2Dynamic tariff (DT) supportThe factory-built gateways will support dynamic tariff configurations in Belgium, Germany, and Netherlands to optimize system behavior for maximum savings.
    3Discharge-to-grid (DTG) supportThe factory-built gateways will support discharge-to-grid functionality in Germany and Great Britain to increase monetary benefit for homeowners by exporting excess energy to the grid at times with high export rates.
  • Microinverters supported: IQ8 Series, IQ7 Series, M Series, and compatible third-party string inverters
  • Batteries supported: IQ Battery 3T/10T, IQ Battery 5P, and AC Batteries
  • Supported system configurations:  
     
    • Belgium, France, Great Britain, Italy, Luxembourg, and Netherlands:
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 5P
    • Austria, Switzerland, Germany, France, Belgium, Netherlands, Spain, Portugal, Denmark, Sweden, and Greece:
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T
    • For all supported countries:
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied Solar Only systems with IQ8 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied Solar Only systems with IQ7 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied Solar Only systems with M Series Microinverters and IQ Gateway Metered or IQ Gateway Standard

This release is being deployed via the factory for new gateways.

IQ Gateway software release notes (8.2.4378)
November 1, 2024

IQ Gateway software version 8.2.4378 improves the performance of the Enphase Energy System for the countries listed below. It also supports busbar overload control and Enphase electric vehicle supply equipment (EVSE) dynamic load balancing Power Control System (PCS) features for the United States and Puerto Rico. 

  • Countries: United States, Bermuda, Brazil, Canada, Mexico, the Philippines, and Puerto Rico
  • Release notes:

    #FeatureDescription
    1Introduces the Power Control (PCS) main panel upgrade avoidance (MPUA) with busbar overload control feature for the United States and Puerto Rico

    Supports MPUA with busbar overload control for Solar Only systems with IQ8 Series Microinverters and grid-tied or grid-forming Solar Plus Batteries systems with IQ8 Series Microinverters and IQ Battery 5P.


    Power Control with busbar overload control accelerates the system payback period by enabling maximum renewable energy generation. This feature enables the safe installation of larger solar and battery systems while maximizing power through a larger backfeed—without costly upgrades to the main panel.

    2Introduces the Enphase IQ EV Charger Power Control System (PCS) feature for the United States and Puerto Rico

    The dynamic load balancing PCS feature in the Enphase IQ EV Charger is designed to monitor the total energy consumption of your home. This feature is crucial as it ensures that the charger adjusts its charging current based on the home’s overall power usage. This is supported for all models of the IQ EV Charger (IQ-EVSE-NA, 40 A, 50 A, 60 A, and 80 A) installed with an IQ Gateway or IQ Combiner.


    This enables the installation of a more powerful IQ EV Charger by avoiding main breaker trips when home loads are extremely high—saving installation costs that would otherwise be incurred by main breaker/service upgrades.

    3Supports full Off-Grid operation
    • Supports microinverter phase association during Off-Grid operation and keeps communication healthy with the gateway.
    • Provides an option to configure the system to operate Off-Grid via the Enphase Installer App or Enphase Installer Portal using a gateway REST API.
       
    4Improves IQ Battery 5P battery management unit (BMU) behavior
    • Improves State-of-Charge (SoC) calibrations under lower and higher SoC conditions.
    • Resolves an issue with battery power conversion units (PCU) pre-charge, which helps recover the battery from extreme low SoC conditions.
    • Fixes an issue with a continuous battery software reset event when a software update is tried while the battery is in a very low SoC condition.
    • Correct an issue where the BMU reads the cell voltage incorrectly and becomes non-operational when the DC Switch is turned off and on.
    • Fixes an issue seen on sites with M Series Microinverters; a rare instance of SoC drop was observed due to manual SoC calibration done by the Battery Controller as part of compensating leakage current.
    • Corrects a sudden jump in the battery SoC value due to forced calibration of the SoC.
    • Addresses incorrect State-of-Health (SoH) calibration when the battery unit charges fully and then discharges more than 50% of its capacity
       
    5Faster battery charging for Off-Grid systems with IQ7 Series Microinverters

    This software release enables faster charging and more reliable state of charge (SoC) recovery for Off-Grid batteries connected to systems with IQ7 Series Microinverters. This improvement is achieved by changing the following parameters for IQ7 Series Microinverters:

    • Reduced entry service time: The entry service time is minimized to just 1 second.
    • Increased ramp rate: The ramp rate is boosted to 100% per second.

    These enhancements are activated only when an IQ System Controller is present and functioning normally. This ensures that the controller manages grid interconnection parameters in accordance with utility requirements, rather than relying solely on the photovoltaic (PV) microinverters.

    6Improves cloud reporting behavior
    • The Enphase App sends homeowner notifications when there is a grid outage and the battery SoC is below 50%, 30%, or a very low SoC. These notifications will be sent until grid power is restored.
    • Increases the amount and frequency of data reported to the Enphase Cloud when IQ Gateway connectivity is restored after loss of internet connection.
    • Fixes an issue where IQ Battery telemetry data gets missed, leading to spikes in graphs on the Enphase Installer Portal.
    • Includes phase imbalance management (PIM) system settings in the configuration report.
    7Bug fixes and feature enhancements
    • Disables the PV breaker open detection in the IQ System Controller (version 1) since it is unnecessary for system controller versions that do not support IQ8 Microinverters.
    • Addresses meter spikes that are observed during software upgrades.
    • Resolves an issue with battery CPU memory access faults during software upgrades.
    • Corrects an issue where the IQ Batteries showed low DC voltages under fully charged conditions.
    • Fixes an issue where microinverters were down due to boot-diode failure.
    • Removes stale alarms caused by time synchronization issues between the gateway and the Enphase App.
    • Enhances security features.
       
  • Gateways supported:
     
    •  United States and Puerto Rico:
       
      • IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES and IEEE 1547-2018 compliant IQ Combiner 4/4C
      • IQ Gateway and IEEE 1547-2018 compliant IQ Gateway
      • IQ Gateway Commercial and IQ Gateway Commercial 2
      • Envoy S Metered and Envoy S Standard for North America
    • Brazil and Philippines:
       
      • IQ Gateway M
      • IQ Gateway Commercial
      • IQ Gateway (only for Brazil)
    • Bermuda, Canada, and Mexico:
       
      • IQ Combiner 5/4, IEEE 1547-2018 compliant IQ Combiner 4
      • IQ Gateway, IEEE 1547-2018 compliant IQ Gateway
      • IQ Gateway Commercial, IQ Gateway Commercial 2 (Only for Canada and Mexico)
  • Microinverters supported:
     
    • United States and Puerto Rico:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2-US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2-US, IQ8M-72-M-US, IQ8P-3P-72-E-US, IQ8H-3P-72-E-US, IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US, IQ8X-80-M-US)
      • IQ7 Series
      • IQ6 Series 
      • M Series
      • S Series
    • Bermuda, Canada, and Mexico:
       
      • IQ8 Series (SKU - IQ8A-72-2-US, IQ8A-72-M-US, IQ8H-208-72-2-US, IQ8H-208-72-M-US, IQ8H-240-72-2-US, IQ8H-240-72-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8M-72-2-US, IQ8M-72-M-US, IQ8P-3P-72-E-US (only for Canada and Mexico), IQ8H-3P-72-E-US (only for Canada and Mexico), IQ8P-72-2-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US, IQ8X-80-M-US (only for Canada))
      • IQ7 Series 
    • Brazil
       
      • IQ8 Series (SKU - IQ8P-72-2-BR)
      • IQ7AM
    • Philippines
       
      • IQ8 Series (SKU - IQ8P-72-2-US)
      • IQ7 Series
  • Batteries supported:
     
    • United States and Puerto Rico:
       
      • IQ Battery 5P, IQ Battery 3/3T/10/10T
    • Bermuda, Canada, and Mexico:
       
      • IQ Battery 5P, IQ Battery 3/3T/10/10T
  • System controllers supported:
     
    • United States and Puerto Rico:
       
      • IQ System Controller 3/3G/2, IQ System Controller
    • Bermuda, Canada, and Mexico:
       
      • IQ System Controller 3/3G/2
  • Supported system configurations:
     
    • The following configurations are supported in the United States and Puerto Rico:
       
      1. Grid-tied (without backup) Solar Only systems with M Series or S Series Microinverters and Envoy S Metered or Envoy S Standard for North America
      2. Grid-tied (without backup) Solar Only systems with IQ6 Series Microinverters and IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES or IQ Gateway
      3. Grid-tied (without backup) Solar Only systems with IQ7 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      4. Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      5. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C
      6. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C
      7. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series or IQ7 Series Microinverters and IQ Gateway Commercial
      8. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Commercial Microinverters (SKU- IQ8P-3P-72-E-US, IQ8H-3P-72-E-US) and IQ Gateway Commercial 2
      9. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IEEE 1547-2018 compliant 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      10. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      11. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      12. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      13. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 5P, Envoy S Metered for North America, and Communications Kit 2
      14. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 3/3T/10/10T, Envoy S Metered for North America, and Communications Kit
      15. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 3/3G, and IQ Combiner 5/5C
      16. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      17. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 2, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      18. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      19. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway, and Communications Kit 2
      20. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      21. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      22. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      23. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      24. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 5P, IQ System Controller 3/3G, Envoy S Metered for North America, and Communications Kit 2
      25. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway, and Communications Kit
      26. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway, and Communications Kit
      27. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 2, IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway, and Communications Kit
      28. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, Envoy S Metered for North America, and Communications Kit
      29. Grid-forming (with backup) Battery Only systems with IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
      30. Grid-forming (with backup) Battery Only systems with IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2
      31. Grid-tied (without backup) Battery Only systems with IQ Battery 5 and IQ Combiner 5/5C or IQ Gateway with Communications Kit 2 or IEEE 1547-2018 compliant IQ Gateway with Communications Kit 2
    • Note: The following features are supported only in these specific configurations.
       
      • Load Control and Generator Support are supported in configurations 15 through 30.
      • Solar circuit control (PV shedding) is supported in configurations 15 through 28.
    • The following configurations are supported in Bermuda, Canada, and Mexico:
       
      1. Grid-tied (without backup) Solar Only systems with IQ7 Series Microinverters and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      2. Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
      3. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
      4. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
      5. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3T/10T, IQ System Controller 2, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 
      6. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3T/10T, IQ System Controller 3/3G, and IQ Combiner 5 or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit
      7. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series or IQ8 Series Microinverters (SKU- IQ8P-3P-72-E-US, IQ8H-3P-72-E-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US), IQ Gateway Commercial (only for Canada and Mexico)
      8. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series or IQ8 Series Microinverters (SKU- IQ8P-3P-72-E-US, IQ8H-3P-72-E-US, IQ8PLUS-72-2-US, IQ8PLUS-72-M-US) and IQ Gateway Commercial 2 (only for Canada)
    • The following configurations are supported in Brazil and the Philippines:
       
      • Grid-tied (without backup) Solar Only systems with IQ7 Series or IQ8P Microinverters and IQ Gateway M or IQ Gateway Commercial
      • Grid-tied (without backup) Solar Only systems with IQ7 Series or IQ8P Microinverters and IQ Gateway (Only for Brazil)
         

This release is being deployed to all IQ Gateway, IQ Combiner, Envoy S Metered, and Envoy S Standard devices stated above through remote software upgrades for existing systems. Note that this release is currently being deployed to sites connected to the internet via Wi-Fi or Ethernet. Sites connected to the internet via Enphase Mobile Connect cellular modems will receive a different software version as a maintenance release at a later date.

 

IQ Gateway software release notes (8.2.4264)
November 1, 2024

 IQ Gateway software version 8.2.4264 supports grid-tied systems with IQ8 Series Microinverters, IQ7 Series Microinverters, M Series Microinverters, or third-party string inverters along with the IQ Battery 3T/10T, IQ Battery 5P, or AC Batteries in Belgium, France, Germany, Great Britain, Luxembourg, and Netherlands.

  • Countries: Belgium, France, Germany, Great Britain, Luxembourg, and Netherlands 
  • Gateways supported: IQ Gateway Metered, IQ Gateway Standard
  • Microinverters supported: IQ8 Series, IQ7 Series, M Series, compatible third-party string inverters
  • Batteries supported: IQ Battery 3T/10T, IQ Battery 5P, AC Batteries
  • Supported system configurations:  
     
    • Belgium, France, Netherlands, and Luxembourg   
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P 
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P 
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P 
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 5P 
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T 
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T 
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T 
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T 
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and AC Batteries 
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries 
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries 
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and AC Batteries 
      • Grid-tied Solar Only systems with IQ8 Series Microinverters and IQ Gateway Metered/IQ Gateway Standard  
      • Grid-tied Solar Only systems with IQ7 Series Microinverters and IQ Gateway Metered/IQ Gateway Standard
      • Grid-tied Solar Only systems with M Series Microinverters and IQ Gateway Metered / IQ Gateway Standard
    • Germany  
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and AC Batteries
      • Grid-tied Solar Only systems with IQ8 Series Microinverters and IQ Gateway Metered/IQ Gateway Standard
      • Grid-tied Solar Only systems with IQ7 Series Microinverters and IQ Gateway Metered/IQ Gateway Standard
      • Grid-tied Solar Only systems with M Series Microinverters and IQ Gateway Metered/IQ Gateway Standard 
    • Great Britain  
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied Solar Only systems with IQ8 Series Microinverters and IQ Gateway Metered/IQ Gateway Standard
      • Grid-tied solar only systems with IQ7 Series Microinverters and IQ Gateway Metered/IQ Gateway Standard
      • Grid-tied solar only systems with M Series Microinverters and IQ Gateway Metered/IQ Gateway Standard 
FeatureDescription
Bug fixes and security enhancementsFixes the issue of mismatching between the data from microinverter measurement and the meters, leading to the erroneous appearance of underproducing microinverters.

This release is being deployed via remote software upgrades for all systems.  

The following known issues have been observed in IQ Gateway software version 8.2.4264: 

Known issues:

IssueDescription
The Enphase Installer App does not support commissioning of the IQ Battery 5P to existing Solar Only sites with gateway software version 7.6.358 in Belgium, France, Luxembourg, and Netherlands 

The IQ Battery 5P is not supported with software version 7.6.358, and the Enphase Installer App cannot upgrade the system to version 8.2.86 which is needed to commission an IQ Battery 5P. Activity to upgrade all Solar Only sites to 7.6.358 to 8.2.4225 is in progress. 

If such a site is encountered, installers should inform Enphase Support to remotely upgrade the site to software version 8.2.4225 before installing and commissioning an IQ Battery 5P. 

IQ Gateway software release notes (8.2.4345)
October 29, 2024

IQ Gateway software version 8.2.4345 is a maintenance software release for grid-tied Solar Only systems.

  • Countries: United States, Canada, and Puerto Rico
  • Gateways supported:  
     
    • IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES, IEEE 1547-2018 compliant IQ Combiner 4/4C
    • IQ Gateway, IEEE 1547-2018 compliant IQ Gateway
    • Envoy S Standard and Envoy S Metered for North America
  • Microinverters supported:  
     
    • IQ8 Series (SKU - IQ8P-72-2-US, IQ8X-80-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8-60-2-US, IQ8PLUS-72-2-US, IQ8M-72-2-US, IQ8A-72-2-US, IQ8H-240-72-2-US, IQ8H-208-72-2-US)
    • IQ7 Series
    • IQ6 Series
    • M Series
    • S Series
  • Supported system configurations:
  1. Grid-tied (without backup) Solar Only systems with M Series or S Series Microinverters and Envoy S Metered or Envoy S Standard for North America
  2. Grid-tied (without backup) Solar Only systems with IQ6 Series Microinverters and IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES or IQ Gateway
  3. Grid-tied (without backup) Solar Only systems with IQ7 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway
  4. Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway

Release notes:

FeatureDescription
Bug fixes and security enhancements
  • Increases the amount and frequency of data reported to the Enphase Cloud when IQ Gateway internet connectivity is restored after a loss of internet connection. This enables quicker backfilling of missing data in customer-facing user interfaces.
  • Fixes an issue where the production and consumption meter open circuit faults are not reporting to the Enphase Installer Portal.
  • Enhances security features.

This release is being deployed to all IQ Gateway, IQ Combiner, Envoy S Metered, and Envoy S Standard devices stated above through remote software upgrades for existing systems. Note that this release is currently being deployed to sites connected to the internet via Wi-Fi or Ethernet. Sites connected to the internet via Enphase Mobile Connect cellular modems will receive a different software version as a maintenance release at a later date.

IQ Gateway software release notes (8.2.4287)
October 25, 2024

IQ Gateway software version 8.2.4287 supports a forecast-based Artificial Intelligence (AI) Optimization engine for Net Billing Tariff (NEM 3.0) customers in California. It also improves the overall performance of the Enphase Energy System.

  • Countries: United States
  • Gateways supported:
    • IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES, IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ Gateway, IEEE 1547-2018 compliant IQ Gateway, Envoy S Metered
  • Microinverters supported:
    • IQ8 Series (SKU - IQ8P-72-2-US, IQ8X-80-M-US, IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, IQ8-60-2-US, IQ8PLUS-72-2-US, IQ8M-72-2-US, IQ8A-72-2-US, IQ8H-240-72-2-US, IQ8H-208-72-2-US), IQ7 Series, IQ6 Series, M Series
  • Batteries supported:
    • IQ Battery 5P, IQ Battery 3/3T/10/10T
  • System controllers supported:
    • IQ System Controller 3/3G, IQ System Controller 2, IQ System Controller
  • Supported system configurations:
  1. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C
  2. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C
  3. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, and IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
  4. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, and IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
  5. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit
  6. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit
  7. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 5P, Envoy S Metered, and Communications Kit 2
  8. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 3/3T/10/10T, Envoy S Metered, and Communications Kit
  9. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
  10. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway and Communications Kit 2
  11. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
  12. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
  13. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
  14. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
  15. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 5P, IQ System Controller 3/3G, Envoy S Metered, and Communications Kit 2
  16. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, and IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway and Communications Kit 1
  17. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, and IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway and Communications Kit
  18. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 2, and IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway and Communications Kit
  19. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, Envoy S Metered, and Communications Kit
  20. Grid-forming (with backup) Battery Only systems with IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C
  21. Grid-forming (with backup) Battery Only systems with IQ Battery 5P, IQ System Controller 3/3G, and IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway and Communications Kit 2
  22. Grid-tied (without backup) Battery Only systems with IQ Battery 5P and IQ Combiner 5/5C or IQ Gateway with Communications Kit 2 or IEEE 1547-2018 compliant IQ Gateway with Communications Kit 2

Note: The following features are supported only in these specific configurations.

  • Load Control and Generator Support are supported in configurations 9 through 21.
  • Solar circuit control (PV shedding) is supported in configurations 9 through 19.
#FeatureDescription
1Supports forecast-based AI Optimization engine for NEM 3.0 customers

Enables a forecast-based AI Optimization engine for NEM 3.0 grid interconnection, and benefits homeowners with tariff-linked savings optimization for Enphase solar and storage systems in California.

  • Supports switching to the AI Optimization profile that optimizes the charging and discharging schedule of Enphase batteries to maximize export credits.
  • Adds a discharge battery to the grid for an export-only system running on the Self Consumption profile to increase savings under NEM 3.0.
2IQ Battery 5P battery management unit (BMU) improvements
  • Improves State-of-Charge (SoC) calibrations under lower and higher SoC conditions.
  • Fixes an issue where the BMU read the cell voltage incorrectly and became non-operational when the DC switch was turned off and on.
  • Addresses an issue seen on sites with M Series Microinverters, where a rare instance of SoC drop was observed due to manual SoC calibration done by the battery controller as part of compensating leakage current.
  • Fixes a sudden jump in the battery SoC value due to forced calibration of the SoC.
  • Resolves incorrect State-of-Health (SoH) calibration when the battery unit charges fully and then discharges more than 50% of its capacity.
3Improved reporting to Enphase Cloud
  • Increases the amount and frequency of data reported to the Enphase Cloud when IQ Gateway connectivity is restored after a loss of internet connection.
  • Fixes an issue where IQ Battery telemetry data gets missed, leading to spikes in graphs on the Enphase Installer Portal.
  • Includes phase imbalance management (PIM) system settings in the configuration report.
4Bug fixes and feature Enhancements
  • Fixes an issue where the IQ Batteries showed low DC voltages under fully charged conditions.
  • Corrects an issue where microinverters were down due to boot-diode failure.

This release is being deployed to all IQ Gateway, IQ Combiner, and Envoy S Metered devices stated above through remote software upgrades for existing systems.

IQ Gateway software release notes (8.2.4225)
August 8, 2024

IQ Gateway software version 8.2.4225 is for grid-tied systems with IQ8 Series, IQ7 Series, and/or M Series Microinverters or compatible third-party string inverters along with the AC Battery or IQ Battery 3T/10T or IQ Battery 5P in Belgium, France, Germany, Great Britain, Luxembourg, and Netherlands. This release supports the dynamic tariff (DT) feature for Belgium and Netherlands, and the discharge to grid (DTG) feature for Great Britain.

  • Gateways supported: IQ Gateway Metered, IQ Gateway Standard
  • Countries: Belgium, France, Germany, Great Britain, Luxembourg, and Netherlands
  • Microinverters supported: IQ8 Series, IQ7 Series, M Series, compatible third-party string inverters
  • Batteries supported: IQ Battery 3T/10T, IQ Battery 5P, AC Batteries (ACB)
  • Supported system configurations: 
     
    • Belgium, France, Netherlands, and Luxembourg 
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and ACB
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and ACB
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and ACB
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and ACB
      • Grid-tied solar-only systems with IQ8 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied solar-only systems with IQ7 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied solar-only systems with M Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
    • Great Britain
       
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with M Series Microinverters and/or IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar-only systems with IQ8 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied solar-only systems with IQ7 Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
      • Grid-tied solar-only systems with M Series Microinverters and IQ Gateway Metered or IQ Gateway Standard
#FeatureDescription
1IQ Battery 5P supportSupports grid-tied solar and storage systems with IQ8 or IQ7 Series Microinverters or third-party string inverters and IQ Battery 5P in Belgium, France, Luxembourg, and Netherlands
2Dynamic tariff (DT) supportSupports dynamic tariff configuration in Belgium and Netherlands to optimize system behaviour for maximum savings
3Discharge to Grid (DTG) supportSupports discharge to grid functionality in Great Britain to increase monetary benefit for homeowners by exporting excess energy to the grid during high export rate periods
4Security updateSoftware security feature updated
5Bug fixes
  • Fixes the issue of G100 export violation in sites with zero power export profiles
  • Fixes the issue of disabling power production in a few of the legacy gateways with the new gateway software and new grid profiles
  • Inclusion of active power export values, active power import values, and power factor at the consumption meter location in the homeowner report

This release is being deployed via remote software upgrades for all systems.

The following known issues have been observed in IQ Gateway software version 8.2.4225:

Known issues:

#IssueDescription
1IQ7 under-production is being erroneously displayed after updating the gateway softwareWith IQ7 Series Microinverters, there is an error in the last reported time stamp, thereby displaying a reduced power production value in the Enphase App. There is no issue observed in actual production. The display issue will be fixed in upcoming software releases.
2Enphase Installer App doesn’t support commissioning of IQ Battery 5P to existing solar-only sites with gateway software version 7.6.358 in France, Netherlands, Belgium, and LuxembourgIQ Battery 5P is not supported with the software version 7.6.358 and Enphase Installer App cannot upgrade the system to the 8.2.86 version which is needed to commission IQ Battery 5P. The activity to upgrade all solar sites to 7.6.358 to 8.2.4225 is under-going. 
If there is such a site in the field, installer should inform Enphase customer care to remotely upgrade the site to 8.2.4225 before installing and commissioning an IQ Battery 5P at the site.
IQ Gateway software release notes (8.2.103)
April 5, 2024

IQ Gateway software version 8.2.103 supports grid-tied storage systems with IQ8/IQ7 Series Microinverters and IQ Battery 5P in Italy and Great Britain.

  • Gateways supported: IQ Gateway Metered, IQ Gateway Metered and Communications Kit 2 (SKU: ENV-IQ-GWM-CK2-INT-KIT) combo package
  • Countries: Italy, Great Britain
  • Microinverters supported: IQ8 Series (SKUs: IQ8MC-72-M-INT, IQ8AC-72-M-INT, IQ8HC-72-M-INT), IQ7 Series, third-party string inverters
  • IQ Batteries supported: IQ Battery 5P
  • IQ Relay supported: Q Relay (Q-RELAY-2-3P-ITA, IQ-RELAY-2-3P-ITA) for Italy
  • Supported system configurations:
    • Great Britain
      • Grid-tied solar-only systems with IQ8 Series Microinverters and IQ Gateway Metered
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 5P
      • Grid-tied solar and storage systems with the third-party inverter, IQ Gateway Metered, and IQ Battery 5P
    • Italy
      • Grid-tied solar-only systems with IQ8 Series Microinverters, Q Relay/ IQ Relay, and IQ Gateway Metered
      • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, Q Relay/ IQ Relay, and IQ Battery 5P
      • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, Q Relay/ IQ Relay, and IQ Battery 5P
      • Grid-tied solar and storage systems with the third-party inverter, IQ Gateway Metered, Q Relay/ IQ Relay, and IQ Battery 5P
#FeatureDescription
1Support for IQ BatterySupports grid-tied solar and storage systems with IQ8/IQ7 Series Microinverters and IQ Battery 5P.
2Support for IQ8 Series MicroinvertersSupports grid-tied solar-only systems with IQ8 Series Microinverters.
3Compliant with phase balancing requirements in Italy to ensure imbalance between phases is below the allowed limit

Supports consumption current transformer (CT) based Phase Imbalance of 6 kVA between phases for three-phase systems in Italy.

Note: M Series Microinverters and compatible third-party inverters are not controllable by IQ Gateway. IQ Gateway does not support Phase Imbalance Management and Power Export Limiting for these inverters.

4Bug fixesFix for Communications Kit 2 appearing as IQ Battery 5P in Live Vitals of Enphase Homeowner App.

This release is being deployed via remote software upgrades for existing systems.

IQ Gateway software release notes (8.2.127)
February 1, 2024

IQ Gateway software version 8.2.127 is a merged release that combines support for 3rd-generation Enphase Energy Systems with Enphase Control Cable-based communication with support for 1st-generation and 2nd-generation Enphase Energy Systems with 2.4 GHz Zigbee-based communication.

  • Countries: Australia, New Zealand, Puerto Rico, and the United States

  • Gateways supported:

    • Puerto Rico and the United States:

      • IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES, IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ Gateway, IEEE 1547-2018 compliant IQ Gateway, Envoy S Metered for North America, and Envoy S Standard for North America

    • Australia and New Zealand:

      • IQ System Controller 3 INT (Gateway included) and IQ Gateway Metered

  • Microinverters supported:

    • IQ8 Series, IQ7 Series, IQ6 Series, M Series, S Series

  • Batteries supported:

    • IQ Battery 5P, IQ Battery 3T/10T, IQ Battery 3/10, AC Battery

    • 3rd-generation IQ Batteries: IQ Battery 5P

    • 2nd-generation IQ Batteries: IQ Battery 3T/10T

    • 1st-generation IQ Batteries: IQ Battery 3/10

    • Legacy Enphase batteries: AC Battery

  • System controllers supported:

    • 3rd-generation IQ System Controllers:

      • IQ System Controller 3/3G for Puerto Rico and the United States

      • IQ System Controller 3 INT for Australia

    • 2nd-generation IQ System Controller: IQ System Controller 2

    • 1st-generation IQ System Controller: IQ System Controller 1

  • Supported system configurations:

The following configurations are supported in Puerto Rico and the United States:

  1. Grid-tied (without backup) Solar Only systems with M Series or S Series Microinverters and Envoy S Metered for North America or Envoy S Standard for North America

  2. Grid-tied (without backup) Solar Only systems with IQ6 Series Microinverters and IQ Combiner 5/5C/4/4C/3/3C/3-ES/3C-ES or IQ Gateway

  3. Grid-tied (without backup) Solar Only systems with IQ7 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway

  4. Grid-tied (without backup) Solar Only systems with IQ8 Series Microinverters and IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway

  5. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C

  6. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, and IQ Combiner 5/5C

  7. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IEEE 1547-2018 compliant 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2

  8. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2

  9. Grid-tied (without backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 1

  10. Grid-tied (without backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 1

  11. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 5P, Envoy S Metered for North America, and Communications Kit 2

  12. Grid-tied (without backup) Solar Plus Batteries systems with M Series Microinverters, IQ Battery 3/3T/10/10T, Envoy S Metered for North America, and Communications Kit 1

  13. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 3/3G, and IQ Combiner 5/5C

  14. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2

  15. Sunlight Backup systems with IQ8 Series Microinverters, IQ System Controller 2, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 1

  16. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C

  17. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IQ Gateway, and Communications Kit 2

  18. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C

  19. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C

  20. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2

  21. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2

  22. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 5P, IQ System Controller 3/3G, Envoy S Metered for North America, and Communications Kit 2

  23. Grid-forming (with backup) Solar Plus Batteries systems with IQ6 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway, and Communications Kit 1

  24. Grid-forming (with backup) Solar Plus Batteries systems with IQ7 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway, and Communications Kit 1

  25. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 2, IEEE 1547-2018 compliant IQ Combiner 5/5C/4/4C or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IQ Gateway or IEEE 1547-2018 compliant IQ Gateway, and Communications Kit 1

  26. Grid-forming (with backup) Solar Plus Batteries systems with M215 or M250 Microinverters, IQ Battery 3/3T/10/10T, IQ System Controller 1/2, Envoy S Metered for North America, and Communications Kit 1

  27. Grid-forming (with backup) Storage Only systems with IQ Battery 5P, IQ System Controller 3/3G, and IQ Combiner 5/5C

  28. Grid-forming (with backup) Storage Only systems with IQ Battery 5P, IQ System Controller 3/3G, IEEE 1547-2018 compliant IQ Combiner 4/4C or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IQ Gateway, and Communications Kit 2

  29. Grid-tied (without backup) Storage Only systems with IQ Battery 5 and IQ Combiner 5/5C or IQ Gateway with Communications Kit 2 or IEEE 1547-2018 compliant IQ Gateway with Communications Kit 2

Note: The following features are supported only in these specific configurations:

  • Load Control and Generator Support are supported in configurations 13 through 28.

  • Solar Circuit Control (PV shedding) is supported in configurations 13 through 26.

The following configurations are supported in Australia and New Zealand:

  1. Grid-tied (without backup) Solar Only systems with IQ8 Series, IQ7 Series, or S Series Microinverters and IQ Gateway Metered

  2. Grid-forming (with backup) Solar Plus Batteries systems with IQ8 Series, IQ7 Series, or S Series Microinverters, IQ System Controller 3 INT, and IQ Battery 5P

Release notes:

All regions:

#

Feature

Description

1

Improvements to commissioning experience

Improves inter-device communication during inventory collection when commissioning Enphase Energy System devices.

Improves meter validation during commissioning.

2

Improvements to system stability

Improves grid synchronization when the system moves from an off-grid state to an on-grid state in a no load condition.

Improves USB enumeration on the IQ Gateway for easier detection of USB-based accessory devices.

Improves Zigbee communication in scenarios such as provisioning, re-establishment of lost communication with a gateway, or following a system black start.

3

Improvements to system functionality

Indicates a Wi-Fi connection error state by turning the Access Point (AP) mode LED to solid amber on the IQ Gateway.

 

Puerto Rico and the United States:

#

Feature

Description

1

Support for new IQ8 Series Microinverters

Supports new IQ Series Microinverters: IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US, and IQ8X-80-M-US.

2

Extension of UL Certified Enphase Power Control features

Support for the UL 1741 Certification Requirement Decision (CRD) for the main panel upgrade (MPU) avoidance feature of Enphase Power Control for grid-tied Solar Plus Batteries systems with IQ Battery 5P/3T/10T. The feature allows installers to:

  • set a software-based current limit at installation time on the back-feed into the main panel from grid-tied Solar Plus Batteries systems.

  • avoid the cost and time of unplanned main panel upgrades.

More information on Enphase Power Control features can be found here.

3

Improvements to commissioning experience

Fixed an issue related to IQ Battery discharge during commissioning.

4

Improvements to field support

Support for handling the Return Merchandize Authorization (RMA) procedure through Enphase field service technicians for the PCBA boards mentioned below:

  • IQ System Controller 3/3G E3 board (SC200G-NA-XA-E3-R3)

  • IQ System Controller 3/3G ESUB board (SC200G-NA-XA-ESUBBoard-R3)

  • IQ Battery 5P BMCC board (B05-BMSRA-0490-O)

  • Envoy board for IQ Combiner (SC-ECB-PCBA-ROW)

5

Improvements to system stability

Fixed an issue where performance reports were not being sent from the IQ Gateway to the Enphase Cloud before timeout expiry.

Fixed an issue in scenarios where the generator line voltage in live status toggles frequently between correct and incorrect values.

Improves stability of the main panel upgrade avoidance feature for grid-tied Solar Only sites.

Fixed an issue with IQ Battery replacement where an older IQ Battery would not retire successfully for replacement with a new battery.

Reduces false positives of battery Current Transformer (CT) error detection.

Improves relay switching logic in grid-forming systems for smoother black starts.

6

Improvements to cellular modem connectivity

Improves network registration behavior to reduce disconnections of the Mobile Connect cellular modem from the cellular network.

 

This release is being deployed to all IQ Gateway, IQ Combiner, Envoy S Metered, and IQ System Controller INT devices stated above through the Enphase Installer App for new systems, and via remote software upgrades for existing systems.

IQ Gateway software release notes (8.2.114)
December 26, 2023

IQ Gateway software version 8.2.114 supports new IQ8HC Series Microinverters in Mexico, and improves State of Charge (SoC) recovery and system stability in Australia and New Zealand.

  • Countries:  Mexico, Australia, New Zealand

  • Gateways supported:

    • Mexico:

      • IQ Combiner 4/4C, IQ Gateway, IEEE 1547-2018 compliant IQ Gateway and IQ Combiner 4/4C, Envoy S Metered

    • Australia and New Zealand:

      • IQ System Controller 3 INT (with integrated IQ Gateway), IQ Gateway Metered

  • Microinverters supported:

    • IQ8HC in Mexico

    • IQ8 Series, IQ7 Series, and S Series in Australia and New Zealand

  • Batteries supported:

    • IQ Battery 3/3T/10/10T in Mexico

    • IQ Battery 5P in Australia and New Zealand

  • Supported system configurations:

The following configurations are supported in Mexico.

  1. Grid-tied Solar Only systems with IQ8HC Microinverters, IQ Gateway or IQ Combiner 4/4C/3/3C/3-ES/3C-ES or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C

  2. Sunlight Backup systems with IQ8HC Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, and IQ System Controller 2

  3. Grid-tied solar and storage systems with IQ8HC Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 2, and IQ Battery 3/3T/10/10T

The following configurations are supported in Australia and New Zealand.

  1. Grid-tied Solar Only systems with IQ8 Series, IQ7 Series, or S Series Microinverters and IQ Gateway Metered

  2. Solar and storage backup systems with IQ8 Series, IQ7 Series, or S Series Microinverters, IQ System Controller 3 INT, and IQ Battery 5P

Release notes:

Mexico:

#

Feature

Description

1

IQ8HC Microinverter support

  • Supports systems in the above configurations with IQ8HC Microinverters.

 

Australia and New Zealand:

#

Feature

Description

1

Improvements to State of Charge (SoC) recovery

  • Supports loads until Very Low State of Charge (VLS) limit of IQ Batteries in an off-grid state.

  • Supports SoC recovery notification on the Enphase App before home power shutdown in an off-grid state when IQ Batteries disconnect from home loads at the VLS limit and charge from solar.

2

Improvements to system stability

  • Improves grid synchronization when the system moves from an off-grid state to an on-grid state in a no load condition.

  • Improves system stability when the system is operating in an off-grid state under a no load condition.

3

Improvements to system stability

  • Fixes an issue where microinverter stops reporting to the IQ Gateway when an IQ Battery 5P is configured in the system.

  • Indicates a Wi-Fi connection error state by turning the Access Point (AP) mode LED to solid amber on the IQ Gateway.

  • Automated recovery of USB communication between the IQ Gateway board and the control board inside the IQ System Controller 3 INT.

  • Disables phase imbalance management (PIM) on single-phase systems.

 

This release is being deployed via remote software upgrades for existing and newly commissioned systems.

IQ Gateway software release notes (7.6.336)
December 8, 2023

IQ Gateway software version 7.6.336 supports IQ7 Series and M Series Microinverters along with IQ Battery 3T/10T and AC Battery for Germany, Belgium, Austria, France, Netherlands, and Switzerland.

  • Gateways supported: IQ Gateway Metered
  • Countries:  Austria, Belgium, France, Germany, Netherlands, Switzerland
  • Microinverters supported: IQ7 Series, M Series, third-party string inverters
  • Batteries supported: IQ Battery 3T/10T, AC Battery
  • Supported system configurations:

    • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
    • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T
    • Grid-tied solar and storage systems with M Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T
    • Grid-tied solar and storage systems with IQ7 Series Microinverters, IQ Gateway Metered, and AC Battery
    • Grid-tied solar and storage systems with M Series Microinverters, IQ Gateway Metered, and AC Battery

    #

    FeatureDescription

    1

    Bug fixes
    • Fixes the issue of multiple USB unplugged events observed in the Enphase Installer Portal.
    • Fixes the issue of microinverters, batteries, and other devices not reporting status by improving the Zigbee communication.
    • Fixes the issue of the Battery Management Unit (BMU) shutting down whenever the IQ battery is idle.
    • Fixes the issue of undesirable power consumption (tare loss) by the battery when in idle state.
    • Fixes the issue of IQ Battery maximum state-of-charge (SoC) being limited to 97% instead of 100%.
    • Fixes the issue of Phase Imbalance Management (PIM) getting enabled for single-phase systems.

     

    This release is being deployed via remote software upgrades for all systems.

IQ Gateway software release notes (7.3.621)
November 3, 2023

IQ Gateway software version 7.3.621 improves system stability.

  • Gateways supported: IQ Gateway, IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IEEE 1547-2018 compliant IQ Gateway and IQ Combiner 4/4C, Envoy S Metered for North America, Envoy S Standard for North America, IQ Gateway Commercial, IQ Gateway M

  • Countries: U.S., Mexico, Canada, Brazil, Philippines

  • Microinverters supported: IQ8 Series, IQ7 Series, IQ6 Series, M Series, S Series

  • Supported system configurations:

  1. Grid-tied Solar Only systems with M Series or S Series Microinverters, Envoy S Metered for North America or Envoy S Standard for North America

  2. Grid-tied Solar Only systems with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C

  3. Grid-tied Solar Only systems with IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C

  4. Grid-tied Solar Only systems with IQ7AM Microinverters, IQ Gateway (residential) in Brazil and Mexico

  5. Grid-tied Solar Only systems with IQ7AM Microinverters, Envoy S Metered EM in Brazil and Philippines (230 V, 60 Hz systems only)

  6. Grid-tied Solar Only systems with IQ7 Series Microinverters, IQ Commercial Gateway in Brazil and Philippines (230 V, 60 Hz systems only)

  7. Grid-tied Solar Only systems with IQ7AM Microinverters, IQ Gateway Commercial in Brazil, Mexico, and Philippines (230 V, 60 Hz systems only)

  8. Sunlight Backup systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, and IQ System Controller 2

  9. Home Essentials Backup or Full Energy Independence systems with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

  10. Home Essentials Backup or Full Energy Independence systems with IQ7 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

  11. Home Essentials Backup or Full Energy Independence systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 2, and IQ Battery 3/3T/10/10T

  12. Home Essentials Backup or Full Energy Independence systems with M215 Series or M250 Series Microinverters, Envoy S Metered for North America, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

Note: The following features are supported only in specific configurations above:

Load Control, Generator Support, and solar circuit control (PV shedding) are supported in configurations 8 through 12.

Grid services are supported in configurations 9 through 12.

Release notes:

# Feature Description
1 Bug Fixes and Feature Enhancements
  1. Fixes an issue with the IQ Gateway due to memory corruption that results in boot failure.
  2. Fixes charge/discharge oscillation issues when:
    1. IQ Battery is at 100% State of Charge (SoC) with Constant Voltage (CV) mode active
    2. Incorrect reference voltage value is set followed by battery reset during CV mode.
  3. Fixes a Battery Management Unit (BMU) L1 error caused by toggling the DC switch of an IQ Battery.
  4. Fixes an issue to avoid BMU RMA due to wrong inventory report.
  5. Fixes the IQ Gateway database corruption observed during a software upgrade.
  6. Fixes an issue where automatic update of IQ Battery firmware failed due to a low SoC condition.

 

This release is being deployed via remote software upgrades for existing systems.

IQ Gateway software release notes (7.3.617)
October 30, 2023

IQ Gateway software version 7.3.617 improves grid transition reliability, system stability, Zigbee communication, Wi-Fi communication, and the commissioning process.

  • Gateways supported: IQ Gateway, IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IEEE 1547-2018 compliant IQ Gateway and IQ Combiner 4/4C, Envoy S Metered for North America, Envoy S Standard for North America, IQ Gateway Commercial, IQ Gateway M

  • Countries: U.S., Mexico, Canada, Brazil, Philippines

  • Microinverters supported: IQ8 Series, IQ7 Series, IQ6 Series, M Series, S Series

  • Supported system configurations:

  1. Grid-tied Solar Only systems with M Series or S Series Microinverters, Envoy S Metered for North America or Envoy S Standard for North America

  2. Grid-tied Solar Only systems with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C

  3. Grid-tied Solar Only systems with IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C

  4. Grid-tied Solar Only systems with IQ7AM Microinverters and IQ Gateway (residential) in Brazil and Mexico

  5. Grid Tied Solar Only systems with IQ7AM Microinverters and IQ Gateway M in Brazil and Philippines (230 V, 60 Hz systems only)

  6. Grid Tied Solar Only systems with IQ7 Series Microinverters and IQ Commercial Gateway in Brazil and Philippines (230 V, 60 Hz systems only)

  7. Grid Tied Solar Only systems with IQ7AM Microinverters and IQ Gateway Commercial in Brazil, Mexico, and Philippines (230 V, 60 Hz systems only)

  8. Sunlight Backup systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, and IQ System Controller 2

  9. Home Essentials Backup or Full Energy Independence systems with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

  10. Home Essentials Backup or Full Energy Independence systems with IQ7 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

  11. Home Essentials Backup or Full Energy Independence systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 2, and IQ Battery 3/3T/10/10T

  12. Home Essentials Backup or Full Energy Independence systems with M215 Series or M250 Series Microinverters, Envoy S Metered for North America, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

Note: The following features are supported only in these specific configurations above.

  • Load Control, Generator Support, and solar circuit control (PV shedding) are supported in configurations 8 through 12

  • Grid Services are supported in configurations 9 through 12

Release notes:

# Feature Description
1 Improvements to system stability 1. Improves the software commissioning update sequence for IQ Batteries by verifying multimode configuration parameter update status via events, and makes sure that during commissioning grid-forming configuration is set. This also disallows the installer from proceeding to functional validation before IQ Batteries are ready, thereby preventing a microgrid collapse and delays in commissioning.

2. Fixes an issue with automatic circuit phase detection for 208 V line-to-line split-phase 120-degree phase shift systems with IQ7 Microinverters.

3. Fixes an issue where grid transition failures happened during the following scenarios:
 
  1. Low Frequency Ride Through (LFRT) events
  2. High Voltage Ride Through (HVRT) events

4. Fixes an issue of microgrid regulatory shutdown after islanding detected due to grid outage, by changing the IQ System Controller off-grid under voltage trip time from 100 ms to 300 ms.

5. Fixes an issue where High-Frequency Ride Through conditions cause microgrid collapse.
2 Enhancements to interface with the Enphase Cloud 1. Supports faster retrieval of Wi-Fi SSIDs from the IQ Gateway to Enphase App using Message Queuing Telemetry Transport (MQTT) protocol over any active internet connection. This lets the homeowner connect to a Wi-Fi network faster and without connecting to the gateway’s local Access Point (AP) mode.

2. Supports automatic AP mode activation whenever an IQ Gateway loses its internet connection. This allows the homeowner to configure the alternate Wi-Fi network via AP mode in the absence of an internet connection, and without pressing the physical AP mode button on the IQ Gateway.

3. Supports setting up the polling and reporting intervals for a system with cell modem connectivity, and prevents reset of interval values due to a change in IQ Gateway diagnostic mode.

4. Improves handling of sending performance reports at regular intervals without any loss of any performance report.

5. Supports REST APIs for enabling and disabling the MID open detection and PV Breaker open detection logics using micro-DMIR change.
3 Improvements to IQ Battery behavior 1. Improves system Sunlight Jump Start response time.

2. Prevents grid transition failure due to IQ Battery microinverters slow ramp, triggered by momentary cessation, kicked in just before anti-islanding detection.

3. Supports enabling and disabling Permission To Operate (PTO) for IQ Batteries on site from the Enphase Installer Portal. The feature prevents IQ Batteries from discharging to load or grid until the permission is enabled, and ensures IQ Batteries are able to maintain a healthy State of Charge (SoC). The status of the IQ Battery function is indicated in Enphase Installer Portal as a stateful event whenever the IQ Battery function is disabled.

4. Fixes an issue where an IQ Battery stops discharging to load when the peak hours overlap with must charge duration.

5. Improves the battery controller detection of microinverters in an IQ Battery by checking the operational state of microinverters.

6. Fixes an issue where the power from IQ Batteries was not being used to support the load when aggregate SoC is greater than reserved SoC.

7. Fixes an issue where the aggregate SoC drops in M Series Microinverter systems when Full Backup mode is selected.

8.Prevents the periodic forced SoC calibration in the Battery Management Unit and maintains battery SoC at approximately 97% by sending a manual SoC calibration message to the BMU after checking cell voltages.
4 Improvements to the commissioning and software upgrading process 1. Improves the software upgrade process by checking versions of all the microinverters in IQ Batteries and triggering automatic upgrade if any microinverter’s firmware version is different from other microinverters.

2. Fixes an issue where the Enphase Installer App was blocked and showing an error while an IQ Gateway software upgrade was in progress.

3. Fixes an issue where multiple firmware upgrade retries happen when the IQ Battery firmware is not updated.

4. Improves the commissioning experience via the Enphase Installer App by logging the upgrade flow in IQ Gateway, including status messages and error messages.

5. Fixes an issue where a software upgrade using the Enphase Installer App fails due to communication loss between the IQ Gateway and the Enphase Installer App.

6. Enhances inventory report with inclusion of the phase association information of each inverter.
5 Improvements to Zigbee and Wi-Fi communication 1. Improves handling of unknown grid mode conditions by increasing the unknown grid mode expiry timer to 12 hours to ensure the IQ System Controller connects back to the grid.

2. Enhances the Zigbee communication loss recovery mechanism during failures.

3. Enhances MQTT client connection loss with MQTT broker recovery mechanism by refreshing the Domain Name System (DNS) cache.

4. Fixes an issue where Zigbee communication between the IQ System Controller and the IQ Battery becomes stuck after an IQ Gateway powers down.

5. Fixes an issue where the Zigbee dongle was undetected after a software upgrade.
6 Bug fixes and feature enhancements 1. Fixes an issue where multiple retries were required to upgrade the software on IQ Batteries.

2. Fixes an issue where repeated battery BMU reset events were reported.

3. Fixes an issue where a generator relay toggles until off-grid to on-grid transition sequence is completed.

4. Fixes an issue where the update manager did not detect the existence of an update image after the software upgrade was interrupted.

5. Removes the repeated “Systems Ghz Comms Signal Low” events which occur after a software upgrade.

 

This release is being deployed via remote software upgrades for existing systems.

Note: Enphase only deploys this software release to system configurations 1 to 7, as described above in the “Supported system configurations” section. Other configurations will be upgraded in a future software release.

IQ Gateway software release notes (8.2.62)
October 5, 2023

The IQ Gateway software version 8.2.62 supports 3rd-generation Enphase Energy Systems (EES) with control wiring between IQ Gateway, IQ System Controller, and IQ Batteries in United States, Puerto Rico, and Australia.

  • Gateways supported:

    • IQ Combiner 5/5C, IQ Gateway, IEEE 1547-2018 compliant IQ Gateway, and Envoy S Metered in the United States and Puerto Rico

    • IQ System Controller 3 INT, with IQ Gateway integrated, and IQ Gateway Metered in Australia

  • Countries: United States, Puerto Rico, Australia

  • Microinverters supported:

    • IQ8 Series, IQ7 Series, IQ6 Series, and M Series in the United States and Puerto Rico

    • IQ8 Series, IQ7 Series, and S Series in Australia

  • Supported system configurations:

The following configurations are supported in the United States and Puerto Rico:

  1. Grid-tied, solar-only systems with M Series Microinverters and Envoy S Metered for the United States and Puerto Rico

  2. Grid-tied, solar-only systems with IQ6 Series Microinverters and IQ Gateway or IQ Combiner 5/5C

  3. Grid-tied, solar-only systems with IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Gateway

  4. Grid-tied solar and storage systems with IQ8 Series or IQ7 Series Microinverters, IQ Gateway or IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Gateway, and IQ Battery 5P

  5. Grid-tied solar and storage systems with M Series Microinverters, Envoy S Metered for North America, and IQ Battery 5P

  6. Sunlight backup systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Gateway, and IQ System Controller 3/3G

  7. Solar and battery backup systems with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 5/5C, IQ System Controller 3/3G, and IQ Battery 5P

  8. Solar and battery backup systems with IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Gateway, IQ System Controller 3/3G, and IQ Battery 5P

  9. Solar and battery backup systems with M215 Series or M250 Series Microinverters, Envoy S Metered for North America, IQ System Controller 3/3G, and IQ Battery 5P

  10. Solar and battery without backup systems with IQ System Controller 3/3G and IQ Battery 5P

  11. Solar and battery without backup systems with IQ Gateway or IQ Combiner 5/5C or IEEE 1547-2018 compliant IQ Gateway, and IQ Battery 5P

Note: The following features are supported only in these specific configurations:

  • Load control, generator support, and solar circuit control (PV shedding) are supported in configurations 6 through 10

The following configurations are supported in Australia:

  1. Solar and battery without backup systems with IQ8 Series or IQ7 Series, or S Series Microinverters and IQ Gateway Metered

  2. Solar and battery backup systems with IQ8 Series or IQ7 Series, or S Series Microinverters, IQ System Controller 3 INT and IQ Battery 5P

Release notes:

All regions:

#

Feature

Description

1

Faster communication between IQ Gateway, IQ System Controller, and IQ Battery

Improved response times and reliability with wired communication between IQ Gateway or IQ Combiner 5/5C, IQ System Controller 3/3G/3 INT and IQ Battery 5P.

2

Support for Enphase Communications Kit 2

Enables compatibility of IQ Battery 5P and IQ System Controller 3/3G with IQ Combiner 4/4C, IQ Combiner 3-ES/3C-ES, and Envoy S Metered by adding Communications Kit 2.

3

Commissioning improvements

Improved commissioning experience and reduced commissioning times with faster provisioning, profile/system-configuration propagation, firmware upgrades, and functional validation.

4

Improved Enphase homeowner experience

Support for periodic health checks on production and consumption current transformers (CTs) and for user notifications if the CTs are not functioning properly.

5

BLE-based Wi-Fi SSID configuration

Improved customer experience with support for home Wi-Fi set up over Bluetooth Low Energy (BLE) with Enphase app version 3.8.0 and above.

 

United States and Puerto Rico:

#

Feature

Description

1

Support for UL-certified Enphase Power Control

Support for UL1741 Certification Requirement Decision (CRD) for Power Control System (PCS)-certified features:

  • IQ Battery Oversubscription feature with IQ Battery 5P: Support for increased battery capacity with Enphase Power Control.

    • Provides higher backup capability for longer durations:

      • With IQ System Controller 3 up to 80 kWh i.e., 16x IQ Battery 5P units

      • With IQ System Controller 3G up to 40 kWh i.e., 8x IQ Battery 5P units

    • Saves labor cost for installers by avoiding dual IQ System Controller-based designs if the homeowner simply wants more battery capacity.

  • Main Panel Upgrade (MPU) Avoidance for PV and Battery systems: Enables installers to set a software-based current limit at installation time on the backfeed into the main panel for solar and battery backup systems and grid-tied, solar-only systems. This enables installers to avoid the cost and time due to an unplanned main panel upgrade. MPU Avoidance for grid-tied, solar and battery systems is coming soon.

  • Aggregate power export limiting: Enables installation of large Enphase PV systems with the provision of a software-based power export limit for regional compliance.

  • IQ Battery 5P import only: Eliminates costs, such as utility charges, for additional net generation output meter (NGOM) installation. Also eliminates feeder transformer upgrade during grid interconnection when solar nameplate is within the feeder transformer thermal limits; however, the addition of a battery requires a transformer upgrade.

2

Support for battery CT

Support for battery CT to improve accuracy of battery usage data and graphical visualizations on Enphase App for homeowners.

Support for battery CT validation checks during the commissioning process in Enphase Installer App.

 

Australia:

#

Feature

Description

1

Support for grid-forming configurations

Support for Enphase IQ System Controller 3 INT enables grid-forming/backup configuration, allowing for resilience during utility grid outages.

2

Support for Storm Guard feature in systems with IQ System Controller 3 INT

The Storm Guard feature in the Enphase App tracks severe weather notifications issued by the Bureau of Meteorology in Australia, which often precede grid outages and help ready your IQ Battery to provide backup power.

3

Support for Common Smart Inverter Profile (CSIP) in South Australia for grid-tied IQ8 Microinverter-based solar-only systems

Support for SA Power Networks (SAPN) interoperability requirements of AUS-CSIP with IEEE 2030.5 communication for Distributed Energy Resources(DER). The implementation supports:

  • Control of site export power.

  • Measurement of site active power, site reactive power, DER active power, DER reactive power, and site voltage.

4

Optimizations to Savings profile

Optimized system behavior in Savings profile for sites in Australia that have a low feed-in tariff—like when the export rate during peak period is lower than the maximum off-peak import rate—to provide more savings.

5

Improved State of Charge (SoC) recovery

Improved State of Charge (SoC) recovery mechanism to prevent recurring microgrid collapses due to low battery SoC. In case of battery shutdown, provides estimated time of battery SoC recovery based on the solar production, when solar power is available.

In the absence of internet connectivity, view solar generation, battery SoC value, and estimated time of SoC recovery completion through the IQ Gateway Wi-Fi AP mode.

Support for automatic load-shedding at user-configurable SoC levels.


This release is being deployed to all IQ Gateway, IQ Combiner, and Envoy S devices stated above through the Enphase Installer App for new systems, as well as via remote software upgrades for existing systems.

IQ Gateway software release notes (7.6.346)
September 4, 2023

IQ Gateway software version 7.6.346 supports new microinverters and battery products for Sweden, Denmark, South Africa, and India. This release enables Consumption CT-based phase imbalance management (PIM) as the default method for complying with phase balancing requirements.

  • Gateways supported: IQ Gateway Metered

  • Countries: Sweden, Denmark, South Africa, and India

  • Microinverters supported: IQ8 Series Microinverters (IQ8MC-72-M-INT, IQ8AC-72-M-INT, IQ8HC-72-M-INT, IQ8P-72-2-INT), compatible third-party string inverters

  • IQ Battery supported: IQ Battery 3T/10T

  • Supported system configurations:

    • Grid-tied solar and storage systems with IQ8 Series Microinverters, IQ Gateway Metered, and IQ Battery 3T/10T for Sweden and Denmark

    • Grid-tied solar and storage systems with compatible third-party string inverters, IQ Gateway Metered, and IQ Battery 3T/10T for Sweden and Denmark

    • Grid-tied Solar Only systems with IQ8 Series Microinverters and IQ Gateway Metered for Sweden and Denmark

    • Grid-tied Solar Only systems with IQ8HC and IQ8P Microinverters and IQ Gateway Metered for South Africa

    • Grid-tied Solar Only systems with IQ8P Microinverters and IQ Gateway Metered for India

    #

    Feature

    Description

    1

    IQ8HC and IQ8P Microinverter support

    • Supports IQ8HC and IQ8P Microinverters with IQ Gateway Metered for South Africa.

    • Supports IQ8P Series Microinverters with IQ Gateway Metered for India.

    2

    IQ Battery support

    • Supports IQ Battery 3T/10T along with IQ8 Series Microinverters for Sweden and Denmark.

    3

    Compliant with phase balancing requirements in Sweden and Denmark to ensure imbalance between phases is below the allowed limit

    • Supports Consumption Current Transformer-based PIM for three-phase systems.

    • 3.68 kVA PIM requirement is supported as specified in section A.3 of EN 50549-1:2019 for Denmark and Sweden.

    Note: M Series Microinverters and compatible third-party inverters are not controllable by an IQ Gateway. IQ Gateway does not support PIM and power export limiting for these inverters.

    4

    Bug Fixes

    • Fixes the issue of continuously triggering AC disconnect due to phase imbalance.

    • Fixes the issue of IQ Battery maximum state-of-charge (SoC) being limited to 97% instead of 100%.

    • Fixes the issue of solar production dropping to zero until the IQ Gateway is rebooted.

    • Fixes the issue of IQ Battery exporting to grid when load is turned off with PIM active.

    • Fixes the issue of solar power production stopping after turning on dynamic phase imbalance limiting.

     

    The following known issues have been observed in IQ Gateway software version 7.6.346:

    Known issues:

    #

    Feature

    Description

    1

    PV production stops randomly for sites with a standard IQ Gateway

    PV production stops whenever a grid profile with power Export Limiting or PIM is enabled at a site with a non-metered IQ Gateway. This issue will be fixed in upcoming software releases.

    2

    A large spike in consumption is reported in the Enphase App when the IQ Gateway software is upgraded to v7.6.346 from v7.6.168

    The Enphase App reports a huge spike in consumption whenever the IQ Gateway software is upgraded to v7.6.346 from v7.6.168. Enphase mitigates this by deleting the records of that day for the system owner, thereby ensuring system owner-facing energy consumption figures are not affected.

 

      This release is being deployed via remote software upgrades for all systems.

IQ Gateway software release notes (7.3.130)
July 7, 2023

IQ Gateway software version 7.3.130 is a security update.

  • Gateways supported: IQ Gateway, IQ Combiner 3/3C/3-ES/3C-ES/4/4C

  • Countries: USA, Mexico, Canada, Brazil

  • Microinverters supported: IQ8 Series, IQ7 Series, IQ6 Series

  • Supported system configurations:

  1. Grid-tied Solar Only systems with IQ6 Series or IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C

  2. Sunlight Backup systems with IQ8 Series Microinverter, IQ Gateway or IQ Combiner 4/4C, and IQ System Controller 2

  3. Home Essentials Backup or Full Energy Independence systems with IQ6 Series or IQ7 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IQ system Controller 1/2 and IQ Battery 3/3T/10/10T

  4. Home Essentials Backup or Full Energy Independence systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, IQ System Controller 2 and IQ Battery 3/3T/10/10T

Note: The following features are supported only in these specific configurations:

  • Load Control, Generator Support, and solar circuit control (PV shedding) are supported in configurations 2, 3 and 4.

  • Grid services are supported in configurations 3 and 4.

Release notes:

# Feature
1 Security Update

 

This release is being deployed via remote software upgrades for existing systems.

IQ Gateway software release notes (7.6.175)
July 7, 2023

IQ Gateway software version 7.6.175 is a security update.

  • Gateways supported: IQ Gateway Metered, IQ Gateway Standard

  • Countries: Australia, India, New Zealand, Indonesia, Germany, Belgium, Italy, Sweden, Denmark, Poland, Portugal, Spain, France, Netherlands, Austria, Switzerland, Czech Republic, Hungary, Ireland, United Kingdom, Turkey

  • Microinverters supported: IQ7 Series, IQ6 Series, M Series

  • Supported system configurations: Grid-tied Solar Only systems with IQ6 Series or IQ7 Series or M Series Microinverters, IQ Gateway Metered or IQ Gateway Standard

Release notes:

# Feature
1 Security Update

 

This release is being deployed via remote software upgrades for existing systems.

IQ Gateway software release notes (7.3.517)
May 12, 2023

IQ Gateway software version 7.3.517 improves system stability, commissioning process, Zigbee communication, and Wi-Fi communication.

  • Gateways supported: IQ Gateway, IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IEEE 1547-2018 compliant IQ Gateway and IQ Combiner 4/4C, Envoy S Metered for North America, Envoy S Standard for North America

  • Countries: USA, Mexico, Canada, Brazil

  • Microinverters supported: IQ8 Series, IQ7 Series, IQ6 Series, M Series, S Series

  • Supported system configurations:

  1. Grid-tied Solar Only systems with M Series or S Series Microinverters, Envoy S Metered for North America, or Envoy S Standard for North America

  2. Grid-tied Solar Only systems with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C

  3. Grid-tied Solar Only systems with IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C, or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C

  4. Sunlight Backup systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, and IQ System Controller 2

  5. Home Essentials Backup or Full Energy Independence systems with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IQ System Controller 1/2 and IQ Battery 3/3T/10/10T

  6. Home Essentials Backup or Full Energy Independence systems with IQ7 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C, or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 1/2 and IQ Battery 3/3T/10/10T

  7. Home Essentials Backup or Full Energy Independence systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 2 and IQ Battery 3/3T/10/10T

  8. Home Essentials Backup or Full Energy Independence systems with M215 Series or M250 Series Microinverters, Envoy S Metered for North America, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

  9. Home Essentials Backup systems with IQ System Controller 1/2 and IQ Battery 3/3T/10/10T


Note: The following features are supported only in these specific configurations.

  • Load Control and Generator Support, and solar circuit control (PV shedding) are supported in configurations 4 through 9.

  • Grid Services are supported in configurations 5 through 9.

Release notes:

 
# Feature Description

1

Improvements to system stability

  1. Fixes issues wherein Sunlight Jump Start does not happen. These are for rare scenarios, like when the System Shutdown Switch is turned back on after it was turned off, or when a generator has failed to start the system.

  2. Fixes a rare issue wherein a system restart does not happen if a generator failure happens while the system is in off-grid mode with the generator connected.

  3. Increases the reliability of on-grid to off-grid system transitions by improving handling of high-frequency ride-through conditions.

  4. Increases the reliability of off-grid to on-grid transitions by improving handling of conditions wherein the grid comes back to normal operation with a low frequency.

  5. Fixes an issue where the IQ System Controller keeps trying to connect DERs and form a microgrid even when the utility grid is available. This is only seen in the rare case when the utility grid voltage/frequency is outside the enter service limits for DERs per the standard followed by the region/utility. This has been fixed by ensuring the IQ System Controller can power the home via grid if the voltages are safe to connect to and keep the DERs disconnected—hence not violating entry service conditions.

2

Improvements to the commissioning and software upgrading processes

  1. IQ Gateway software now reports the status of battery inverter mode (grid-tied, multi-mode on-grid, multi-mode, off-grid, etc.) to the Enphase Installer App. This is displayed in the Enphase Installer App during functional validation.

  2. Reduces commissioning time for IQ8 Microinverters by optimizing the communication between the IQ Gateway and IQ8 Microinverters during provisioning. Provisioning steps repeated due to IQ8 Microinverters rebooting post-propagation of system configuration are reduced, leading to a reduction in overall provisioning time.

  3. Enhances logging for IQ Battery 3/3T/10/10T and IQ System Controller 1/2 upgrades by reporting the names of the files, along with download start and download end events, to the Enphase Cloud.

  4. Improves the reliability of software updates when the internet connection is via a cellular modem. This is achieved by increasing the timeout limit for specific files that are large in size, which in turn enables more retries during the download of these files over cellular data.

  5. Reduces the time taken to update the IQ System Controller 1/2 firmware from the IQ Gateway by providing flow control during transfer of packets via Zigbee.

  6. Improves the software upgrade process to automatically handle conditions like low state of charge and the system going off-grid and back on-grid, as well as devices losing Zigbee connection and then reconnecting.

  7. Fixes an issue wherein IQ8 Microinverters fail provisioning. This is a very rare scenario wherein an IQ8 Microinverter fails to receive system configuration during provisioning.

  8. Fixes an issue wherein the IQ Gateway reboots upon completion of device commissioning using the Enphase Installer App.

  9. Fixes an issue where the IQ System Controller 1/2 firmware is not updated immediately after commissioning and functional validation.

  10. Fixes an issue where system configuration files are propagated to the IQ Battery 3/3T/10/10T and IQ System Controller 1/2 multiple times.

  11. Fixes an issue where specific IQ Battery models (SKU: B03-A01-US00-1-3) were not upgrading to the new Battery Management Unit (BMU) firmware and causing reset events.

  12. Fixes an issue where circuit phase auto-detection feature was not supported for IQ7 Series Microinverter systems.

3

Improvements to system behavior

  1. IQ System Controller 2 includes a hardware protection feature wherein it detects AC voltage on either side of the PV breaker and goes to a safe state if there is a significant difference in the magnitude of the AC voltage readings from either side of the breaker while the internal PV relay is closed. The PV relay is the built-in protection for grid-forming IQ8 Series Microinverters on the PV or solar port (DER1) of the IQ System Controller 2. This rule has been modified to be active only when:

    • The IQ System Controller 2 is commissioned.

    • IQ8 Series Microinverters are connected to the PV port.

    • There is a 20 V delta in AC voltage readings from either side of the PV breaker after 30 ms of the PV relay closing (this was 20 ms earlier).
     

    Once triggered, the rule raises the PV breaker open error and only opens the PV relay to keep the system safe, instead of all relays as on previous software releases. In addition, the PV breaker open error automatically clears after 30 seconds for the first three occurrences. If any more occurrences are detected, then the error persists and requires Enphase Support intervention to clear.

    These changes improve the hardware protection feature while avoiding false detection and any homeowner or installer inconvenience due to false detection.

  2. Retrieves more debugging data from the Battery Management Unit (BMU) for IQ Batteries, and sends the same to the Enphase cloud to enable better system monitoring and debugging.

  3. Improves the handling of Grid Services commands by ensuring the commands persist across IQ Gateway reboots.

4

Improvements to IQ Battery behavior

  1. Supports battery-only backup systems (configuration 9 as described in “Supported system configurations” above) by resolving issues like the IQ Gateway rebooting and the IQ Battery 3/3T/10/10T getting disconnected due to false triggers of the PV breaker open rule. Improvements to the PV breaker open rule are described in the “Improvements to system behavior” section.

  2. Fixes an issue wherein the status of the DC ON/OFF switch was not accurately communicated by the IQ Battery 3/3T/10/10T and IQ Gateway to the Enphase Cloud.

  3. Fixes an issue wherein the IQ Battery 3/3T/10/10T would not maintain the reserve state of charge (SoC) by charging from the grid.

  4. Validates if the Current Transformers (CTs) used for monitoring consumption are missing or have failed. The IQ Battery 3/3T/10/10T are set to an idle mode if Consumption CTs are missing or have failed to ensure the Import-Only mode per IQ Battery 3/3T/10/10T UL Power Control System (PCS) Certification Requirements Decision (CRD) is not violated in case of CT failures.

  5. Fixes an issue wherein the IQ Battery 3/3T/10/10T does not charge with maximum power when the system is off-grid with a generator connected.

5

Improvements to Zigbee and Wi-Fi communication

  1. Reduces profile propagation time from the IQ Gateway to the IQ System Controller 1/2.

  2. Supports remote restarts of the Zigbee communication processes inside the IQ Gateway software through the Enphase Installer Portal. This is to aid in remote debugging and improve customer support capabilities.

  3. Improves the connectivity to Wi-Fi networks by ensuring the parameters used to tune the Wi-Fi module’s front-end are appropriate.

  4. Fixes the display of an incorrect battery state in Live Vitals in the Enphase App and Enphase Installer App when batteries have lost Zigbee communication.

6

Bug fixes and feature enhancements

  1. Reports load name and battery profile via local API to the Enphase App to enable the app to display these details when the system has lost cloud connectivity and is reporting to the app via local connectivity (i.e., via the local area network, assuming the phone running the app and the IQ Gateway are on the same local area network).

  2. Enhances IQ Gateway security by integrating the Cloud Certification Authority (CCA) into software signing.

  3. Fixes an issue wherein the IQ Battery 3/3T/10/10T was not charging when the Power Export Limit (PEL) is enabled in the grid profile and the battery is in savings mode.

  4. Fixes an issue wherein many “Systems GHz Comms Signal Low” events are sent to the Enphase Cloud. Note that the excessive number of events are not visible to the homeowner or installer. The number of events is reduced in this software release to enable the Enphase Support team to use internal tools to better support homeowners and installers.

  5. Fixes an issue where the Consumption CT measures a very high value at the time of an IQ Gateway software upgrade.

  6. Fixes an issue wherein, post-upgrade to 4.40.04 firmware, IQ7+ Microinverters lose communication and do not produce power.

 

This release is being deployed via the Enphase Installer App for new systems as well as via remote software upgrades for existing systems. Remote software upgrades for this release will exclude systems that have only cellular connectivity.

IQ Gateway software release notes (7.3.467)
May 10, 2023

IQ Gateway software version 7.3.467 is the next release version compliant with IEEE 1547-2018 for residential applications. This software version only supports the new IEEE 1547-2018 compliant IQ Gateway (SKU: ENV2-IQ-AM1-240) and IQ Combiner 4/4C (SKUs: X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C).

  • Gateways supported: IQ Gateway (SKU: ENV2-IQ-AM1-240), IQ Combiner 4/4C (SKUs: X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C)

  • Countries: USA

  • Microinverters supported: IQ8 Series, IQ7 Series

  • Supported system configurations:

  1. Grid-tied Solar Only systems with IQ7 Series or IQ8 Series Microinverters and IQ Gateway or IQ Combiner 4/4C

  2. Sunlight Backup systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, and IQ System Controller 2

  3. Home Essentials Backup or Full Energy Independence systems with IQ7 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T

  4. Home Essentials Backup or Full Energy Independence systems with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, IQ System Controller 2, and IQ Battery 3/3T/10/10T

Note: The following features are supported only in these specific configurations.

  • Load Control, Generator Support, and solar circuit control (PV shedding) are supported in configurations 2, 3, and 4.

  • Grid Services are supported in configurations 3 and 4.

Release notes:

# Feature Description
1 Bug fixes for IQ7 Series Microinverters Fixes an issue wherein post-upgrade to 4.40.04 firmware, IQ7+ Microinverters lose communication and do not produce power.

 

This release is being deployed via the Enphase Installer App for new systems, as well as via remote software upgrades for existing systems with an IEEE 1547-2018 compliant IQ Gateway or IQ Combiner. Installers must contact Enphase Support when installing Enphase Energy Systems with an IQ Gateway running software version 7.3.463 or lower.

IQ Gateway software release notes (7.3.514)
March 17, 2023


IQ Gateway software version 7.3.514 is the next release version with improvements in system stability, commissioning process, and enhanced Zigbee and Wi-Fi communications.

  • Gateways supported: IQ Gateway, IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IEEE 1547-2018 compliant IQ Gateway and IQ Combiner 4/4C, Envoy S Metered for North America, Envoy S Standard for North America

  • Countries: USA, Mexico, Canada, Brazil

  • Microinverters supported: IQ8 Series, IQ7 Series, IQ6 Series, M Series, S Series

  • Supported system configurations:

  1. Grid-tied Solar Only system with M Series or S Series Microinverters, Envoy S Metered for North America
  2. Grid-tied Solar Only system with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C
  3. Grid-tied Solar Only system with IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C
  4. Sunlight Backup system with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, and IQ System Controller 2
  5. Home Essentials Backup or Full Energy Independence system with IQ6 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C, IQ System Controller 1/2 and IQ Battery 3/3T/10/10T
  6. Home Essentials Backup or Full Energy Independence system with IQ7 Series Microinverters, IQ Gateway or IQ Combiner 3/3C/3-ES/3C-ES/4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 1/2 and IQ Battery 3/3T/10/10T
  7. Home Essentials Backup or Full Energy Independence system with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C or IEEE 1547-2018 compliant IQ Gateway or IEEE 1547-2018 compliant IQ Combiner 4/4C, IQ System Controller 2 and IQ Battery 3/3T/10/10T
  8. Home Essentials Backup or Full Energy Independence system with M215 Series or M250 Series Microinverters, Envoy S Metered for North America, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T
  9. Home Essentials Backup with IQ System Controller 1/2, and IQ Battery 3/3T/10/10T


Note: The following features are supported only in specific configurations above:

  • Load control, generator support, and solar circuit control i.e., PV shedding are supported in configurations 4 through 9.

  • Grid services are supported in configurations 5 through 9.

Release notes:

# Feature Description
1 Improvements to System Stability a. Fixes issues wherein Sunlight Jump Start does not happen. These are for rare scenarios, like when the System Shutdown Switch is turned back on after it was turned off or when a generator has failed to start the system.

b. Fixes a rare bug wherein a system restart does not happen if a generator failure happens while the system is in off grid mode with the generator connected.

c. Increases the reliability of on-grid to off-grid system transitions by improving handling of high frequency ride through conditions.

d. Increases the reliability of off-grid to on-grid transitions by improving handling of conditions wherein the grid comes back to normal operation with a low frequency.
2 Improvements to the Commissioning and Software Upgrading Process a. Gateway software reports the correct status of battery inverter mode (grid-tied, multi-mode on-grid, multi-mode off-grid etc.) to the Enphase Installer App. This is displayed in the Enphase Installer App during functional validation.

b. Reduces commissioning time for IQ8 PV microinverters by optimizing the communication between the gateway and IQ8 microinverters during provisioning. Provisioning steps repeated due to IQ8 rebooting post propagation of system configuration are reduced, leading to time savings.

c. Enhances logging for battery and system controller upgrades by reporting the names of the files along with download start and download end events to Enphase Cloud.

d. Improves the reliability of software updates when the internet connection is via a cellular modem. This is achieved by increasing the timeout limit for specific files that are large in size.

e. Reduces the time taken to update the IQ System Controller firmware from the gateway by providing flow control during transfer of packets via Zigbee.

f.Improves the software upgrade process to automatically handle conditions like low state of charge, the system going off-grid and then coming back on-grid as well as devices losing Zigbee connection and then reconnecting.

g.Fixes an issue wherein IQ8 Series Microinverters fail provisioning. This is a very rare scenario wherein an IQ8 microinverter fails to receive system configuration during provisioning.

h.Fixes an issue wherein the gateway reboots upon completion of device commissioning using the Enphase Installer App.

i.Fixes an issue where the IQ System Controller firmware is not updated immediately after commissioning and functional validation.

j.Fixes an issue where system configuration files are propagated to batteries and the system controller multiple times.

k.Fixes an issue where specific IQ Battery models (SKU: B03-A01-US00-1-3) were not upgrading to the new Battery Management Unit (BMU) firmware and causing reset events.
3 Improvements to System Behavior a. IQ System Controller 2 includes a hardware protection feature wherein it detects AC voltage on either side of the PV breaker and goes to a safe state if there is a significant difference in the magnitude of the AC voltage readings from either side of the breaker while the internal PV relay is closed. The PV relay is the built-in protection for IQ8 grid forming microinverters on the PV or solar port (DER1) of the IQ System Controller 2. This rule has been modified to be active only when:
  • The IQ System Controller 2 is commissioned.
  • IQ8 Series Microinverters are connected to the PV port.
  • There is a 20 V delta in AC voltage readings from either side of the PV breaker after 30 ms of the PV relay closing (this was 20 ms earlier).
b. Retrieves more debugging data from the Battery Management Unit (BMU) for IQ Batteries and sends the same to Enphase cloud to enable better system monitoring and debugging.

c. Improves the handling of Grid Services commands by ensuring the commands persist across IQ Gateway reboots.
 
4 Improvements to IQ Battery Behavior a. Supports battery-only backup systems (configuration 9 as described in “Supported System Configurations” above) by resolving issues like gateway rebooting and batteries getting disconnected due to false triggers of the PV breaker open rule. Improvements to the PV breaker open rule are described in the “Improvements to System Behavior” section.

b. Fixes an issue wherein the status of the DC ON/OFF switch was not accurately communicated by the batteries and gateway to the cloud.

c. Fixes an issue wherein batteries would not maintain the reserve state of charge (SoC) by charging from the grid.

d. Validates if current transformers (CTs) used for monitoring consumption are missing or have failed. Batteries are set to an idle mode if consumption CTs are missing or have failed to ensure the Import-Only mode per IQ Battery 3/3T/10/10T UL Power Control System (PCS) Certification Requirements Decision (CRD) is not violated in case of CT failures.

e. Fixes an issue wherein IQ Batteries do not charge with maximum power when the system is off grid with a generator connected.
5 Improvements to Zigbee and Wi-Fi Communication a. Reduces profile propagation time from the IQ Gateway to the IQ System Controller. .

b. Supports remote restarts of the Zigbee communication processes inside the IQ Gateway software through the Enphase Installer Portal. This is to aid in remote debugging and improve customer support capabilities.

c. Improves the connectivity to Wi-Fi networks by ensuring the parameters used to tune the Wi-Fi module’s front end are appropriate.

d. Fixes the display of an incorrect battery state in Live Vitals in the Enphase Homeowner and Installer Apps when batteries have lost Zigbee communication.
6 Bug Fixes and Feature Enhancements a. Reports load name and battery profile via local API to the Enphase Homeowner App to enable the app to display these details when the system has lost cloud connectivity and is reporting to the app via local connectivity (i.e., via the local area network, assuming the phone and the gateway are on the same local area network).

b. Enhances the IQ Gateway security by integrating the (Cloud Certification Authority) CCA into gateway signing.

c. Fixes an issue wherein IQ Batteries were not charging when the Power Export Limit (PEL) is enabled in the grid profile and the battery is in savings mode.

d. Fixes an issue wherein a lot of “Systems GHz Comms Signal Low” events are sent to the Enphase cloud. Note that the excessive number of events is only seen by Enphase employees. The number of events is reduced in this software release to enable customer support teams to use internal tools to better support system owners and installers.

 

This release is being deployed in factories to all IQ Gateway, IQ Combiner, and Envoy S devices stated above. It is also being released via the Enphase Installer App for new systems as well as via remote software upgrades for existing systems. Remote software upgrades for this release will exclude systems that have only cellular connectivity.

IQ Gateway software release notes (7.3.466)
January 6, 2023

IQ Gateway software version 7.3.466 is the next release version compliant with IEEE 1547-2018 for residential applications. It supports only the new IEEE 1547-2018 compliant IQ Gateways (SKU: ENV2-IQ-AM1-240) and IQ Combiners (SKUs: X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C).

  • Gateways supported: IQ Gateway (SKU: ENV2-IQ-AM1-240), IQ Combiner 4/4C (SKUs: X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C)

  • Countries: USA

  • Microinverters supported: IQ8 Series, IQ7 Series

  • Supported system configurations:

  1. Grid-tied Solar Only system with IQ7 Series or IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C
  2. Sunlight Backup system with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, and IQ System Controller 2
  3. Home Essentials Backup or Full Energy Independence system with IQ7 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, IQ System Controller 1/2, and IQ Battery 3/3T/10/10T
  4. Home Essentials Backup or Full Energy Independence system with IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C, IQ System Controller 2, and IQ Battery 3/3T/10/10T

Note: The following features are supported only in specific configurations above:

  • Load control, generator support, and solar circuit control i.e., PV shedding are supported in configurations 2, 3, and 4.

  • Grid services are supported in configurations 3 and 4.

Release notes:

# Feature Description
1 Compliant with IEEE 1547-2018 Regulations (also present in IQ Gateway software release 7.3.463) a. Supports limiting PV active power as a percentage of the nameplate.

b. Supports enable or disable of permit service to allow or stop PV power production remotely.

c. Meets the enter service criteria, where PV power production does not start unless the system voltage and frequency are within the specified limits for the prescribed delay time. After the delay time, power is ramped linearly at a rate not exceeding the nameplate power divided by the enter service period.

d. Maintains exported active power at the point of common coupling (PCC) at less than 10% of the aggregate system rating.

e. Supports the following mutually exclusive reactive power control modes:
 
  1. Constant power factor mode: the system operates at a constant power factor

  2. Voltage-reactive power mode (volt-var): the reactive power of the system is controlled as a function of voltage using a volt-var curve

  3. Active-reactive power mode (watt-var): the reactive power of the system is controlled as a function of active power using a watt-var curve

  4. Constant reactive power mode: the system maintains a constant reactive power

f. Supports active power control for temporary frequency disturbances according to a parameterized frequency-droop (freq-watt) characteristic.

g. Supports bringing the net power export to zero before going off-grid (when commanded to do so by user).

h. Supports interoperability and data exchange over the local communication interface using IEEE 2030.5, including:
 
  1. Provision of nameplate information

  2. Provision of monitoring information, and

  3. Ability to read and write function and mode setting
2 Bug Fixes Fixes an issue where sites were unable to commission with a Zigbee range extender and could not proceed with functional validation.

 

This release is being deployed in factories to the IEEE 1547-2018 compliant IQ Gateway and IQ Combiner devices. IQ Gateway software 7.3.466 release is being deployed via remote software upgrades for the new sites that receive IQ Gateways with software version 7.3.463 or lower version from the factory for Enphase Energy Systems. Installers have to contact Enphase Support while installing Enphase Energy Systems at the site with IQ Gateway which has software version 7.3.463 or lower version from the factory.

 

IQ Gateway software release notes (7.3.463)
December 7, 2022

IQ Gateway software version 7.3.463 is the next major release version compliant with IEEE 1547-2018 for residential applications. It supports Grid-tied Solar Only system with new IEEE 1547-2018 compliant IQ Gateways (SKU: ENV2-IQ-AM1-240) and IQ Combiners (SKUs: X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C).

  • Platforms supported: IQ Gateway (SKU: ENV2-IQ-AM1-240), IQ Combiner 4/4C (SKUs: X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C)

  • Geographies: USA

  • Microinverters supported: IQ8 Series, IQ7 Series

  • Supported system configurations: Grid-tied Solar Only system with IQ7 Series/IQ8 Series Microinverters, IQ Gateway or IQ Combiner 4/4C

Release notes:

# Feature Description
1 Compliant with IEEE 1547-2018 Regulations a. Supports limiting PV active power as a percentage of the nameplate.

b. Supports enable or disable of permit service to allow or stop PV power production remotely.

c. Meets the enter service criteria, where PV power production does not start unless the system voltage and frequency are within the specified limits for the prescribed delay time. After the delay time, power is ramped linearly at a rate not exceeding the nameplate power divided by the enter service period.

d. Maintains exported active power at the point of common coupling (PCC) at less than 10% of the aggregate system rating.

e. Supports the following mutually exclusive reactive power control modes:
 
  1. Constant power factor mode: the system operates at a constant power factor

  2. Voltage-reactive power mode (volt-var): the reactive power of the system is controlled as a function of voltage using a volt-var curve

  3. Active-reactive power mode (watt-var): the reactive power of the system is controlled as a function of active power using a watt-var curve

  4. Constant reactive power mode: the system maintains a constant reactive power

f. Supports active power control for temporary frequency disturbances according to a parameterized frequency-droop (freq-watt) characteristic.

g. Supports bringing the net power export to zero before going off-grid (when commanded to do so by user).

h. Supports interoperability and data exchange over the local communication interface using IEEE 2030.5, including:
 
  1. Provision of nameplate information

  2. Provision of monitoring information, and

  3. Ability to read and write function and mode setting

 

This release is being deployed in factories to the IEEE 1547-2018 compliant IQ Gateway and IQ Combiner devices.